Peak Control was switched the wrong way round. Confirming Peak Control "enabled" from Home Assistant turned it off on the inverter (and "disabled" turned it on). Peak and Load Control use 0 = on, the opposite of the TOU switches; this is now correct and confirmed on a Cygni. If you confirmed Peak Control from HA with an earlier version, check it in the Dyness app. Load Control follows the same documented convention but has not been verified on hardware.
TOU power is limited to 2,000 W. Dyness now rejects TOU group power above 2,000 W ("Request parameter exception") — the limit in their API documentation, now enforced on their side. The power slider stops at 2,000 W, Stage reports values that are too high (including ones saved by earlier versions), and the error message explains the cause. Set faster charge rates in the Dyness app. Automations that set TOU power above 2,000 W will fail — keep them at or below 2,000 W.
Other
The set_tou_schedule action description documents the HH:mm and 2,000 W rules.