FCP file descriptor byte decoded per TS 102 221 Table 11.5 (not ISO
7816-4 Table 14, the file-descriptor audit): the shareable flag is b7
(0x40), not b8; the EF-structure bits are 000 no info / 001 transparent
/ 010 linear fixed / 110 cyclic with 011/100/101/111 RFU (the old
decode fabricated "linear fixed TLV" / "linear variable" / "linear variable
TLV" / "cyclic TLV"); and b6–b4 = 111 with b3–b1 = 010 is RFU, not
"SIMPLE-TLV" (TS 102 221 has no SIMPLE-TLV row).
FCP life cycle status byte: any value with b8–b5 non-zero is now
proprietary (was: b8 only), so b6/b5-set values are no longer misread
as RFU.
Application power consumption voltage class E decoded at b6 (0x20),
per Table 6.1 ATR coding (was b5).
UICC characteristics now decodes the clock-stop preference/condition
bits b4–b3 (no preferred level / high / low when allowed; never / unless