Skip to content

v0.2.0

Latest

Choose a tag to compare

@bdecl bdecl released this 27 Oct 22:57
· 7 commits to main since this release
f6ffd01

Requires Home Assistant 2026.10 or newer.

Changes

  • Shared Modbus connection. Units are taken from Home Assistant's modbus integration (async_get_unit, async_get_temporary_unit for the scan) instead of an own pymodbus client: every integration addressing the same host and port shares one connection and queues its requests. No own Python requirements; the manifest depends on modbus.
  • Sleeping inverters at night. After dusk the ECU keeps serving the last values of its inverters (a few watts, grid voltage, state MPPT). An inverter whose measurement registers have not changed for 15 minutes is shown as asleep: power and currents 0, voltage, frequency and temperature unknown, state Sleeping, energy kept. Inverters online / producing count only fresh data. New Last data update sensor per inverter.
  • Optional ECU ID in the setup and reconfigure forms. The ECU is not visible over Modbus: its ID names the ECU device after its model (215 ECU-C, 2160 ECU-R, 2162 ECU-R Pro) and shows model and serial number.
  • Inverters named after their serial number, e.g. QT2-3 (17556), instead of the Modbus address. Existing entries keep their entity ids.
  • Setup stops at once with "cannot connect" when nothing answers.
  • No deprecated Home Assistant usages: OptionsFlowWithReload instead of an update listener (2026.12), via_device_id instead of via_device (2027.8).
  • Brand images (icon, logo, dark logo) in brand/.
  • CI on Python 3.14 against Home Assistant 2026.10.0; README, example dashboards updated.

Tested

  • Test suite on Home Assistant 2026.10.0 and 2026.10.4 (simulated ECU).
  • On a real ECU-C with nine QT2-3 (pre-releases v0.2.0b1 to b6): shared connection, polling, limit write, frozen data at night shown as asleep after 15 minutes, no deprecation warnings, ECU ID added through Reconfigure without changing entity ids.

Upgrading from 0.1.x: update Home Assistant to 2026.10 or newer first. Existing config entries keep working.