Repository navigation
VoltDeck 2026.10-v10
VoltDeck 2026.10-v10 makes the battery check practical for small packs and normal receiver/servo idle current.
- The current limit is now at least 0.30 A. A 450 mAh pack therefore permits 0.30 A, allowing reported idle readings of 0.1–0.2 A to complete the check.
- The existing capacity scaling and 1.50 A ceiling remain: 0.375 A at 2500 mAh and 0.60 A at 4000 mAh. Limits at and above 2000 mAh are unchanged.
- The check still requires 10 continuous seconds, valid readings and a voltage span of at most 0.20 V for the whole pack. Counter disagreement, cell/type checks, counter-reset acceptance and fresh confirmation checks retain their behavior.
- No new setting or settings-format change is needed. Existing Deck/Digital layouts, telemetry selections, alarms and flight logging are preserved.
This release uses the physically tested 0.30 A candidate with only its VERSION declaration changed for stable publication.
Install VoltDeck-2026.10-v10.zip through FrSky Suite → Lua library → Install Lua scripts → Install scripts. Suite displays 26.10.10. Back up the model and widget files, keep the existing configured widget and cfg/dat files, then restart ETHOS and check the version in Configure widget. If the old version remains, preserve a backup of and remove only scripts/VoltDeck/main.luac, then restart ETHOS.