Repository navigation
New in 0.1.26
A review of the whole application against its own documents, and of the manual against the application. The manual is corrected throughout where it described an earlier version. In the application:
- The gas reserve charged a hold to the wrong cylinder where the way up switches gas at the depth it starts from, such as a safety stop begun on the bottom gas and breathed on a deco gas: the reserve was kept in air and nothing of the deco gas. Fixed.
- The CNS oxygen clock no longer recovers under water. It gave back exposure wherever the oxygen was low, a lean mix at depth or a shallow stop included, which is more lenient than the published method and the computers that follow it. It recovers on the surface only, halving every ninety minutes, and the manual says that figure is a convention.
- A saved plan is judged as the planner judged it: under its own oxygen limits, END limit, safety stop and ascent rate, rather than the model's defaults, so a plan's page and the planner no longer disagree.
- A correction to a dive's cylinders reaches its calculations. A volume or mix put right on the dive was ignored by the recording's SAC and decompression, and an edit through a recording's tab discarded corrections made on the dive's other cylinders.
- A mix read from a dive computer was named one percent low where the driver's fraction fell a shade under: EAN29 arrived as EAN28, and any 20 to 22 percent mix as air.
- A Bluetooth download that fails says why: that the computer did not answer in time, offers no service the app can drive, or what went wrong; a link lost part way is told from a slow computer, and a dive the library cannot parse is counted and said rather than dropped.
- A dive recorded by two computers and rejoined from two stretches no longer gains a second gas source from the repeated gas report.
- Dives imported from a review land with the number their row showed, a skipped dive no longer shifting the ones after it, and a dive that arrived with its own number keeps it.
- A recording without a water density is worked out at 1020 kg/m³ throughout; SAC and the decompression model used two different fallbacks.
- Maintenance that has been redone no longer reads as expired, and the settings form says the default for Water and O₂ narcotic and offers Revert once you have chosen one.
- A gradient factor under one percent is refused where it is written, in a plan file or the settings, rather than accepted and refused later.
- On Windows and Linux: Override no longer fills a box with text the model refuses; a chosen item is looked up again after Reload, so a save reaches the file; numbers are no longer formatted in the machine's locale; a rating can be cleared; the plan form no longer runs the model on every repaint; a link out of the manual cannot crash the window.
- On Android: the first listing of a logbook's folder reports a folder gone rather than crashing; an export truncates what it writes over; a switch between light and dark during a download no longer ends it; a cloud drive whose app has stopped is reported rather than read as an empty logbook; back leaves no draft behind in a form.
- In the terminal front end: a refusal or an import's note is no longer cleared before it can be read; a remark with Windows line breaks places its mentions correctly; an entry that will not read is no longer dropped when another is added or removed.
Windows 10 and 11: Yemoja-0.1.26.msi. It replaces an earlier Yemoja. The installer is not signed, so Windows warns on first run that the publisher is unknown: choose More info, then Run anyway.
Linux: yemoja_0.1.26_amd64.deb for Debian, Ubuntu, Mint and their relatives (install with your package manager, or sudo apt install ./yemoja_0.1.26_amd64.deb), or Yemoja-0.1.26.tar.gz for any distribution: unpack it anywhere and start Yemoja/bin/Yemoja. 64-bit Intel and AMD processors only. Reading a dive computer has not yet been tried on Linux, and computers that speak only classic Bluetooth are not read there.
Android 12 and later: Yemoja-0.1.26.apk. Install it by opening the file on the phone and allowing installs from that source when asked. Dive computers are read over Bluetooth: a Perdix 2 and an i330R have been read on a Pixel 9a.
The figures from the planner and the calculations come from a model, not a dive computer, and may be wrong; see the manual inside the app.