Repository navigation
Quickstart
Languages: English | 繁體中文
Welcome to Stuffy Meter — a Wi-Fi air-quality monitor measuring CO₂, temperature, relative humidity, dew point, absolute humidity, and VOC index (volatile organic compounds).

Everything you need to set up and manage your monitor is built directly into its web dashboard — no extra apps, cables, or cloud accounts are required.
Tip — Find your monitor automatically: Once your monitor is on your Wi-Fi, open cmwang.dev/stuffy-meter/discovery/ on any phone or computer on the same network to automatically discover your Stuffy Meter(s) and jump straight to their dashboard.
| USB edition | Battery edition | |
|---|---|---|
| Power | USB-C | USB-C + 18650 backup battery (keeps running for 2–3 days during a power cut) |
| How to tell | No side switch (rev 3.2) |
Slide switch (BAT ON / OFF) on the right side (rev 4.1) |
Steps marked Battery edition apply only to the Battery edition.
- What you need
- Power it on
- Connect to Wi-Fi
- Find your monitor & use the web dashboard
- Recommended settings
- Calibration
- Telegram push alerts &
/statusbot - Firmware updates (Over Wi-Fi)
- Home Assistant & smart home integrations (optional)
- Button, LED & screen guide
- Troubleshooting
- Your Stuffy Meter, a USB-C cable, and any standard 5 V USB power adapter (phone charger).
- Battery edition: one flat-top, unprotected 18650 Li-ion cell (2500–3500 mAh, purchased separately — protected or button-top cells are a few millimeters longer and will not fit; battery protection is already built into the Stuffy Meter board).
- A 2.4 GHz Wi-Fi network and its password (the monitor does not support 5 GHz-only Wi-Fi).
- A phone, tablet, or computer with a web browser on the same Wi-Fi.
Best placement: Place the monitor at desk or shelf height with open airflow around the vents. Avoid direct sunlight, air-conditioning vents, humidifiers, open window drafts, or breathing directly onto the sensor, as these can temporarily skew temperature and CO₂ readings.
Plug the monitor into USB-C power. The start-up screen shows the firmware version and checks the sensors:
-
First time (or after a reset): the screen shows the Wi-Fi setup page with a QR code and its setup Wi-Fi name (
StuffyMeter-xxxxxx), and the LED blinks slowly. - Already configured: the screen shows your live readings.

Warm-up note: CO₂ readings settle within a few minutes. The VOC index shows warming up for the first minute; afterwards,
100represents your room's baseline air quality (higher values indicate cooking, cleaning, or other VOC sources).
(Skip this section if you have the USB edition.)
- Slide the power switch on the right side to OFF and unplug USB-C.
- Gently pry the lid straight up using the notch under the USB-C port on the left and the notch on the right side (lift straight up — do not tilt toward the front display).
- Insert the 18650 cell with
+facing right (toward the slide switch; double-check polarity and never insert the cell backwards). - Lower the lid straight down until it clicks all around, slide the switch to BAT ON, and plug USB-C back in.

| Status bar icon | Meaning |
|---|---|
| Bolt + battery | Charging (temperature and humidity cards show amber while the charger warms the board) |
| Green battery | Fully charged |
Battery + %
|
Running on backup battery (USB power lost) |
Red / over battery |
No battery installed, or slide switch is OFF |
While on battery, the monitor automatically saves power (30 s CO₂ interval, dimmer screen, slower Wi-Fi retries if the router is also down). If the cell runs empty, the monitor safely sleeps until USB power returns and restarts automatically.
-
Join the setup Wi-Fi: scan the QR code on the monitor's screen with your phone camera, or manually connect to the Wi-Fi network
StuffyMeter-xxxxxx(no password). -
Open the setup page: it usually opens automatically. If not, open
http://192.168.4.1/in your browser.Phone says "No Internet"? That is normal — the setup hotspot is local only. Tap Keep / Stay Connected (if
http://192.168.4.1/still does not load, temporarily turn off mobile/cellular data during setup). - Select your Wi-Fi: tap your 2.4 GHz Wi-Fi network and enter its password.
-
Personalize in one step: optionally enter a Room name (e.g.
Living Roomor客廳— shown on the monitor's screen, web dashboard, Telegram alerts, and Home Assistant immediately). Language and Time zone are auto-detected from your browser so the clock, night mode, and interface work right away (you can adjust them here or anytime later in Settings). -
Set an admin password: choose a password (at least 6 characters, no
:) and confirm it. This protects your settings and updates (username is alwaysadmin), while readings stay viewable by anyone on your home network. (Ticking Skip leaves settings open to anyone on your Wi-Fi.) - Tap Connect. Once connected, the page displays your monitor's local addresses — for example
http://192.168.0.42/andhttp://stuffymeter-a1b2c3.local/— plus a direct link to Settings for night mode and Telegram alerts. - Switch your phone back to your home Wi-Fi and open that address (or scan the monitor's Dashboard QR Code page, or visit cmwang.dev/stuffy-meter/discovery/ to find it automatically).

The temporary StuffyMeter-xxxxxx hotspot closes automatically one minute after connecting.
Moving to another Wi-Fi later: hold the MODE button for 3 seconds and release it to reopen the Wi-Fi setup hotspot.
Short-press MODE on your Stuffy Meter until the Dashboard QR code page appears (right after Device info), then scan it with your phone camera. The QR code encodes http://<current-IP>/, opening the live web dashboard directly on iOS and Android without relying on .local mDNS.

Open cmwang.dev/stuffy-meter/discovery/ on any phone, tablet, or computer connected to the same Wi-Fi, then click Scan Network (allow Local Network Access if your browser prompts). It automatically discovers all Stuffy Meter devices on your LAN, shows live readings, lets you blink a monitor's LED to identify it, and opens its dashboard with one tap — you can even install it to your home screen as an app.

Open http://stuffymeter-xxxxxx.local/ or the monitor's IP address directly in any browser on your Wi-Fi. You can always check both addresses on the monitor's Device info or Dashboard QR code screens.
| Air quality | CO₂ (ppm) | VOC index | What it means & what to do |
|---|---|---|---|
| Good (Green) | < 800 |
< 150 |
Fresh indoor air — comfortable for focus and sleep. |
| Moderate (Yellow) | 800–1200 |
150–250 |
Getting slightly stuffy — consider cracking a window or running a fan. |
| Poor (Orange) | 1200–1600 |
250–400 |
Stuffy air that can cause drowsiness or headaches — ventilate soon. |
| Bad (Red) | > 1600 |
> 400 |
Poor ventilation or strong fumes (cooking, cleaning, smoke) — open windows now. |
Tip: Outdoor fresh air is around 420 ppm CO₂. A VOC index of
100is your room's normal average (relative to the past 24 hours). Comfortable indoor relative humidity is typically 40–60 %.

| Tab | What you can do |
|---|---|
| Dashboard | Live CO₂, temperature, humidity, VOC index, dew point, air-quality rating, and interactive 1 hour, 24 hours, and 7 days charts |
| Settings | Customize name, language, time zone, brightness, night mode, thresholds, Telegram alerts, MQTT, and updates |
| Device | View sensor/network health, run sensor self-tests, and calibrate temperature and CO₂ |
| Firmware | Check for updates, install over Wi-Fi, or adjust the automatic nightly update window |
| Logs | Live diagnostic log viewer |
Both the monitor's dashboard and cmwang.dev/stuffy-meter/discovery/ support installation as a standalone app icon:
-
iPhone / iPad (Safari): tap Share (
↑), then Add to Home Screen. - Android (Chrome) / Desktop (Chrome / Edge): tap the install banner at the top of the page (or browser menu > Install app / Add to Home screen).
Open the Settings tab (log in as user admin with your admin password). Changes take effect immediately without rebooting unless noted.

| Setting | What it does |
|---|---|
| Device name | Friendly room name (e.g. Living Room or 客廳). Shown in the web dashboard, the monitor's TFT status bar, Telegram alerts, and Home Assistant. |
| Language | Display language (English or 繁體中文) for the monitor screen, Telegram notifications, and web dashboard default. |
| Time zone | Time zone string for the on-screen clock, night mode, and nightly updates (default CST-8 for Taiwan / UTC+8; copy yours from the table below). |
| Active brightness / Dim after idle | Adjust screen brightness (5–100 %) and optionally dim or turn off the screen after inactivity. |
| Night mode | Automatically dim or turn off the screen during sleeping hours (e.g. 22 to 7 at 0 %); pressing MODE wakes the screen for 30 seconds. |
| Auto-cycle pages | Automatically rotate through the readings and trend chart screens every N seconds (0 = stay on main screen). |
| Use Fahrenheit (°F) | Switch temperature display between °C and °F. |
| CO₂ / VOC alert thresholds | Customize when air quality changes from Good -> Moderate -> Poor -> Bad (defaults: CO₂ 800 / 1200 / 1600 ppm; VOC 150 / 250 / 400). |
| Battery brightness / Screen off on battery | (Battery edition) Lower brightness or keep the screen off during power cuts to maximize battery runtime (pressing MODE wakes it for 30 s). |
Common time zone strings (copy & paste into Time zone):
| Region | Value |
|---|---|
| Taiwan / Hong Kong / Singapore (UTC+8) | CST-8 |
| Japan / South Korea (UTC+9) | JST-9 |
| US Pacific (Los Angeles / Seattle) | PST8PDT,M3.2.0,M11.1.0 |
| US Eastern (New York / Toronto) | EST5EDT,M3.2.0,M11.1.0 |
| UK (London) | GMT0BST,M3.5.0/1,M10.5.0 |
| Central Europe (Berlin / Paris) | CET-1CEST,M3.5.0,M10.5.0/3 |
| Australia Eastern (Sydney / Melbourne) | AEST-10AEDT,M10.1.0,M4.1.0/3 |

The electronics and backlight warm the enclosure slightly, which the monitor compensates for automatically. For the best accuracy:
- Let the monitor run for 1–2 hours in its normal location with the case closed.
- Place a trusted reference thermometer beside it.
- Open Device > Temperature calibration, enter the reference temperature, and save.
(Repeat if you significantly change screen brightness or night mode.)
- Automatic: by default, automatic self-calibration (ASC) keeps CO₂ accurate as long as the room receives fresh outdoor air (~400 ppm) about once a week.
-
Manual: place the monitor outdoors or by a wide-open window for at least 3 minutes, then open Device > CO₂ forced recalibration, enter
420(typical outdoor CO₂), and calibrate.
Receive instant phone notifications whenever CO₂ or VOC exceeds your threshold, plus recovery notifications when the air clears — directly from the monitor, with no extra server required.
- Open Telegram, message
@BotFather, send/newbot, follow the prompts, and copy your Bot token (looks like123456789:AAH...). - Open your new bot in Telegram and tap Start (or add it to a family group).
- Find your Chat ID using
@userinfobotin Telegram (or use@yourchannelfor a public channel). - On the monitor's web dashboard, go to Settings > Telegram alerts:
- Turn on Enable Telegram alerts.
- Paste your Bot token and Chat ID.
- Optionally set custom CO₂ / VOC alert thresholds (
0uses your main Bad threshold) and Alert cooldown (default 60 minutes). - Optionally enable Bot /status command so you can send
/statusto your bot anytime to get live readings.
- Click Save, then click Send test message to verify delivery.
Settings:

Result — example alert in Telegram:

For more details, see Telegram Alerts.
Your Stuffy Meter updates itself over Wi-Fi — no USB cable is needed.

- Automatic updates (on by default): the monitor checks GitHub for new releases and installs updates automatically at night (default 02:00–05:00 local time; Battery edition updates only while on USB power). If a new version ever fails health checks, the monitor automatically rolls back to the previous working version.
- Update immediately: open the Firmware tab, click Check now, and if an update is available click Update now.
-
Manual file upload: download the
.binmatching your board (board3.2.binfor USB edition orboard4.1.binfor Battery edition — not_factory.bin) from Releases and upload it under Firmware > Upload firmware.
All Wi-Fi credentials, room name, calibration, and settings are preserved across updates.
To help spot firmware crashes, sensor faults, and OTA rollbacks early, Stuffy Meter sends a brief anonymous health ping once a day (plus a structured crash summary if the firmware ever reboots abnormally) via Google Analytics 4 Measurement Protocol (non_personalized_ads: true).
- Zero personal data: no Wi-Fi SSID, hostname, room name, raw MAC address, or air-quality readings (CO₂, temperature, humidity, VOC) are ever sent. Devices are identified only by a one-way hashed anonymous ID.
- Easy opt-out: uncheck Send anonymous health & crash telemetry during Wi-Fi setup, or turn off Anonymous telemetry anytime under Settings → System.
The official HACS integration ha-stuffy-meter connects directly to your Stuffy Meter over your local Wi-Fi — 100% local, zero cloud, and no MQTT broker required:
-
Install via HACS: click the Open HACS Repository button above (or in Home Assistant open HACS →
⋮→ Custom repositories, addhttps://github.com/chiehmin/ha-stuffy-meterwith category Integration, and search for Stuffy Meter), click Download, and restart Home Assistant. -
Automatic discovery: after restarting, go to Settings → Devices & services. Any Stuffy Meter on your Wi-Fi appears automatically under Discovered — click Add (or Configure) and confirm. (You can also add it manually by IP or
stuffymeter-xxxxxx.local.) -
Ready to use: all sensors (CO₂, temperature, humidity, VOC index, dew point, absolute humidity, air quality, Wi-Fi signal, uptime, firmware version, plus battery & USB power on Battery edition), update availability status, and the Identify button work with no password. Enter your admin password in the integration options only if you set one on the monitor and want to trigger Restart, Check for updates, or Firmware OTA installation from Home Assistant. Renaming your monitor (
Device name) or updating firmware syncs automatically. - In-app OTA firmware updates: the native Firmware update entity surfaces new releases automatically in Settings → Updates and on the device page with release notes links, live download progress (0–100%), and one-click OTA installation. Click Check for updates anytime to check immediately.
Setup — automatic discovery & confirmation:

Result — Stuffy Meter device, live sensors & firmware update status in Home Assistant:

One-click OTA firmware update directly in Home Assistant:

Already running an MQTT broker? Open Settings → MQTT on your monitor's web dashboard, enter your MQTT broker address (e.g. mqtt://192.168.1.10:1883), username, and password, keep Home Assistant discovery turned on, and click Save. See MQTT & Home Assistant.
Live JSON readings (/api/status), history (/api/history), and Prometheus metrics (/metrics) are available directly on port 80. For multi-room long-term history (5-year retention), pre-built Grafana dashboards, alert rules in Docker, and /metrics scraping & PromQL reference, see Prometheus & Grafana. For JSON endpoint details, see REST API.

| Action | Result |
|---|---|
Short press MODE
|
Switch to next screen page (or wake screen if dimmed/off) |
Double press MODE
|
Jump back to main readings page |
Hold 3 s, then release MODE
|
Open Wi-Fi setup hotspot (StuffyMeter-xxxxxx) |
Hold 10 s MODE
|
Factory reset (countdown shown on screen; release early to cancel) |
Press ↻ pinhole |
Hardware restart (use a paper clip) |
Screen pages (short-press MODE to cycle; labeled BOOT on earlier enclosures): Main dashboard -> CO₂ (1 h) -> CO₂ (24 h) -> Temperature & Humidity (24 h) -> VOC index (24 h) -> Device info (IP, hostname, Wi-Fi, firmware) -> Dashboard QR code (http://<ip>/). Returns to the main screen after 1 minute of inactivity (auto-cycle skips the QR page to stay on readings and info).
| LED pattern | Meaning |
|---|---|
| Short blip every 3 s | Normal operation |
| Slow blink (1 Hz) | Connecting to Wi-Fi, or setup hotspot open |
| Fast blink (5 Hz) | Sensor error (recovering automatically) |
| Double blink | Air quality is Bad |
| Rapid flicker | Firmware update in progress, or Identify active |
| Problem | Solution |
|---|---|
| Cannot join Wi-Fi | Confirm your network is 2.4 GHz (not 5 GHz-only) and double-check the password. Hold MODE for 3 seconds to reopen Wi-Fi setup. |
Cannot find the monitor / .local does not open |
Short-press MODE until the Dashboard QR code page appears and scan it with your phone camera (opens http://<ip>/ directly without mDNS), or open cmwang.dev/stuffy-meter/discovery/ and click Scan Network. |
| Forgot admin password | Hold MODE for 10 seconds to factory reset, then reconnect via the Wi-Fi setup hotspot. |
| Temperature reads slightly high | Allow 1–2 hours of warm-up with the case closed, then calibrate under Device > Temperature calibration. |
| Battery edition won't turn on with a new cell | Plug in USB-C once with the switch at BAT ON to wake the battery protection circuit. |
| Battery edition screen goes black after a long outage | The battery reached its safe cutoff level; it restarts automatically once USB power returns. |
| Screen stays black after plugging in | Make sure the MODE button is not stuck pressed while plugging in USB-C, then unplug and replug. |