PQC Computational Energy Testing Guide
This wiki page serves as a comprehensive guide for using the automated PQC computational energy usage testing tools provided by PQC-LEO. It covers the general requirements for using the testing scripts and details on how to run the testing script.
Before proceeding, review the basic environment preparation and setup guides for instructions on configuring the testing environment.
The automated testing script for evaluating the PQC computational energy usage is located in the scripts/test_scripts directory. Please ensure that the basic environment setup has been performed before proceeding with this category of testing. This information can be found in the Energy Usage Testing Guide page.
This testing script provides an automation layer for the comp_energy_tester tool, a C-based executable that performs post-quantum cryptographic operations while measuring energy consumption. The script allows users to configure the testing parameters and launch the executable, which utilises the PQC implementations available in the Liboqs library to execute the selected cryptographic operations for a user-specified number of iterations.
As part of the testing process, the script will automatically handle configuring the system state for energy usage testing, which includes setting the CPU performance to maximum and selecting a specific target CPU core. This helps improve consistency for energy usage evaluation, although background processes and thermal throttling can still affect measurements. Additionally, a 60 second baseline energy usage reading is taken by default before the testing process begins, which serves as a reference point for evaluating the energy consumption of the cryptographic operations.
The baseline measurement duration can be configured by passing --energy-baseline-duration=<TIME> when calling the testing machine script. The specified duration must be a positive whole number of seconds.
Energy usage metrics are stored on the collection machine and, by default, parsed there into structured CSV files after the collection session completes.
Notice: Support for automated configuration of a system fan is not currently available in the provided testing scripts. This is due to the variety of system types and fan control methods available, making a universal solution challenging. Future versions aim to address this limitation. It is highly recommended to manually configure the system fan (if applicable) to a fixed speed before testing to prevent variances in the fan speed during testing impacting the system's power draw, skewing the energy usage results.
There are two machines and scripts that must be configured and launched for the energy usage testing process, which include: the collection machine and the testing machine. Each machine has its own respective script that must be launched to ensure the testing process runs smoothly, with the testing machine script responsible for signalling the collection machine to poll the energy meter at the appropriate times during testing.
Please ensure you have thoroughly read the general instructions and environment setup for the collection machine in the Energy Usage Testing Guide page before proceeding with testing, as it contains important details on setting up the collection machine and energy meter for testing.
Once the environment for the collection machine is properly set up, the collection machine script can be launched using the following command:
./energy_metric_collector.sh
Please then select the PQC Performance Energy Testing collection type and proceed to configure the relevant collection parameters as prompted by the script. For details on configuring the collection parameters, please refer to the Energy Usage Testing Guide page.
Once the environment is ready and the collection machine has been activated, the testing machine script can be launched using the following command:
./pqc_performance_energy_test.sh
Additional command line arguments can be passed to the testing script which enable advanced customisation of the automated testing process. For details of all advanced testing options, please refer to the Energy Usage Testing Guide page. Of these advanced options, the ones supported by the PQC computational energy usage script are:
--energy-baseline-duration=<TIME>--use-custom-sys-state--use-custom-eng-control-ports
Before testing begins, the script will prompt the user to configure two categories of parameters, which include:
- The Control Signaller
- The Testing Parameters
The first set of parameters to be configured is related to the control signaller, which is responsible for signalling the collection machine to poll the energy meter at the appropriate times during the testing process. The user will be prompted to select the control signalling method that they wish to use, with the following options available:
- Serial
- Network
If the user selects serial, the serial port to be used for serial communication must be specified. If the user selects network, the local IP of the testing machine and the remote IP of the collection machine must be specified. For details on setting up the required communication environment for control signalling, please refer to the Energy Usage Testing Guide page.
The second set of parameters to be configured is related to the testing parameters, which include:
| Prompt | What the option sets |
|---|---|
| Enter the number of iterations for each test (e.g., 1000) | Number of iterations to be performed for each algorithm's respective cryptographic operations. |
| Enter the number of test runs to perform | Number of separate test runs to execute. |
| Enter the energy meter polling rate in milliseconds (0 for no delays between polls) | Polling interval in milliseconds for the energy meter; set 0 for continuous/no delay between polls. |
After testing completes, the raw output from the computational energy usage testing is stored in the following directory on the collection machine:
test_data/up_results/energy_test_results/pqc_performance_energy_results/machine_x
Where machine_x refers to the assigned Machine-ID. If no ID was specified, the default ID of 1 is used.
By default, the automated collection script will trigger the parsing system upon completion of testing, which processes the raw output into structured CSV files. These parsed results are saved in:
test_data/results/energy_test_results/pqc_performance_energy_results/machine_x
To skip automatic parsing and only output the raw test results, pass the --disable-result-parsing flag when launching the collection machine script:
./energy_metric_collector.sh --disable-result-parsing
For complete details on parsing functionality and a breakdown of the collected energy usage metrics, refer to the following documentation: