Fixes components settled wrongly when a mask read times out during setup, such as while an inverter wakes at dawn.

Fixed

  • A timed-out mask read no longer settles what the inverter serves. Before, a denied meter block was kept and polled indeterminate values (on a 4.4 KTLX-G3, load consumption total echoed the solar total), a declared charge cut-off was dropped, and a higher PV string count was missed, each until the next setup. Setup now fails on such a timeout and the next poll asks again; a refusal is still final.

Reproduced and verified on a 4.4 KTLX-G3 by dropping the mask read through a proxy. PR #82.