Overview
This dataset contains structural (T1-weighted), resting-state functional (fMRI),
and diffusion tensor imaging (DTI) data from patients diagnosed with
Obsessive-Compulsive Disorder (OCD).
Participants
Patients (n = 41) meeting DSM-5 criteria for OCD, aged 18-50 years, with or
without pharmacological treatment at the time of scanning.
Inclusion criteria
- Diagnosis of OCD according to DSM-5 criteria.
- Age between 18 and 50 years, with or without pharmacological treatment.
- Minimum educational level: primary school completed.
- Intellectual coefficient within normal range (80-120, per standardized
intelligence scale). - Signed informed consent.
Exclusion criteria
- Comorbidity with another psychiatric disorder.
- Presence of a neurological disorder.
- History of substance abuse.
- Any contraindication for MRI examination.
Elimination criteria (post-acquisition)
- Structural brain abnormalities identified on MRI.
- Voluntary withdrawal from the study.
MRI Acquisition
Images were acquired on a 3.0 T Discovery MR750 scanner (GE Healthcare) with a
32-channel head coil, at the Unidad de Resonancia Magnética (URM), Instituto
de Neurobiología, UNAM. Participants were positioned supine with foam padding
for head fixation and earplugs for auditory protection.
T1-weighted (anat)
- Sequence: 3D FSPGR (Fast Spoiled Gradient Recalled Echo)
- Orientation: sagittal
- TR/TE: 8.2/3.2 ms
- Acquisition matrix: 256 x 256
- Field of view: 256 mm
- Slice thickness: 1 mm, contiguous
Resting-state fMRI (func)
- Sequence: EPI GRE (Echo Planar Imaging Gradient Echo)
- TR/TE: 2000/40 ms
- Acquisition matrix: 64 x 64
- Slices: 35 axial, 4 mm
- Duration: 10 minutes
- Task: eyes open, central fixation cross, instructed to remain still and awake
Diffusion tensor imaging (dwi)
- Sequence: EPI2 (GE), 60 diffusion directions, 2 mm isotropic slices
- TR/TE: 7000/60.5 ms
- Flip angle: 90 degrees
- Acquisition matrix (PE): 128, reconstructed to 256
- Parallel imaging reduction factor: 2
- Phase encoding direction: j
Quality control
Scans were visually inspected; runs with head motion greater than 2 mm or
atypical structural findings were discarded.
Data conversion
Raw DICOM images were converted to NIfTI format using dcm2nii
(version 1.0.20181125 for T1/func; dcm2niix v1.0.20210317 for dwi).