Repository navigation
Home

This is the mean spectrum of the Type B QPO of MAXI J1820+071. It is fitted with the model:
phabs x (gaussian + disk + nthComp + relxillCp)
where the fit parameters can be seen below. The reduced chi-squared is 1.716.
| Component | Parameter | Unit | Value |
|---|---|---|---|
| phabs | nH | 1022 | 0.150* |
| gaussian | LineE | keV | 2.400* |
| gaussian | Sigma | keV | 0.283±3.365e-02 |
| gaussian | norm | 3.476e-02±1.206e-02 | |
| diskbb | Tin | keV | 0.771±0.142 |
| diskbb | norm | 3426.62±3245.76 | |
| nthComp | Gamma | 1.955±1.539 | |
| nthComp | kT_e | keV | 30.016±400.105 |
| nthComp | kT_bb | keV | linked to diskbb Tin |
| nthComp | inp_type | 0/1 | 0.0* |
| nthComp | Redshift | 0.0* | |
| nthComp | norm | 7.983e-03±1.080 | |
| relxillCp | Index1 | 8.642±13.13 | |
| relxillCp | Index2 | 2.996±5.890 | |
| relxillCp | Rbr | 2.563±1.392 | |
| relxillCp | a | 0.983±3.105e-02 | |
| relxillCp | Incl | deg | 63.220±2.864 |
| relxillCp | Rin | -1.000* | |
| relxillCp | Rout | 990.0* | |
| relxillCp | z | 0.0* | |
| relxillCp | Gamma | linked to nthComp Gamma | |
| relxillCp | logxi | 3.697±1.201 | |
| relxillCp | Afe | 4.477±13.10 | |
| relxillCp | kTe | keV | linked to nthComp kT_e |
| relxillCp | refl_frac | -1.398±1.247e05 | |
| relxillCp | norm | 8.036e-03±716.5 | |
| value* denotes that it was frozen |
Fitting this mean spectrum was difficult. Any parameters that mean the same thing physically are linked, such as the common parameters between nthComp and relxillCp are linked. The reasoning here is that relxillCp is based on nthComp. The reflection fraction in relxillCp was made negative, which means it functions as only a reflection spectrum, without the intrinsic continuum. That way, the nthComp flux is not double-counted. The nthComp on which relxill is based assumes a very cold disk, appropriate for AGN. This is not suitable for X-ray binaries, and so the other nthComp component in the model is really fairly different. The reason relxillCp was added into the model was to attempt to account for reflection, such as a relativistically broadened iron line. It is quite possible that this source is too bright for NICER (see the residuals at the higher energies) and it is not yet understood how the detector responds to sources like this. Due to this, we are uncertain if the model in completely accurate, but still wished to share what we ran into.
We acknowledge and thank J. Miller at the University of Michigan for his help in fitting this mean spectrum.