Development build for testing on an MHO900. Not a release. Built from the branch oos-mho: the fixes from hp197's tests of mho-dev-35 and -37 and his pull requests #561 and #562 (issue #4). Please test carefully and report back with oos-mho-report (or mho-setup.py <scope-ip> report).

Verified on hp197's MHO98 (mho-dev-35): fan, counter, peak detect's picture, 50 and 100 ms/div with the edge at the trigger point, roll, the generator board found, generator 1's offset.

Fixed in this build, not yet verified on hardware:

  • Logic analyser diagnostics: with the LA on, the log shows every 50 frames what its words hold and the board's LA words, to find its sample rate on the MHO900 (it showed the wrong time base, then a flat line, on skluehspies' MHO98).
  • The empty start of some frames at 50 to 200 µs/div (Normal and peak detect): frames where the board triggered away from the trigger point are no longer shown. The log counts them, to find the cause.
  • 50 ms/div: the 0 V stretch after the trigger point is not fixed yet; the log now says where the record holds one word for long.
  • The generator's shape DC no longer crashes the screen.
  • Peak detect: the measurements no longer count twice the frequency.
  • Memory depth: a fixed depth takes the nearest rate the unit's recording has (it stayed at 10 k before).
  • Generator 1 puts out every shape: sine, square, ramp (with its symmetry), pulse (with its duty), arbitrary, noise and DC, also after a start by OOS (the output's scale words are set now, #562). Verified on hp197's MHO98: sine, square, ramp, pulse, noise and DC at the right amplitude and frequency. Up to 2 Vpp, ±1 V offset.
  • Bode with the built-in generator: verified on hp197's MHO98 through a cable (flat within +0.14/−0.05 dB from 100 Hz to 1 MHz).

Still open: the logic analyser's sample rate (time base wrong, then flat), 50 Ω (set it on the screen: OOS's SCPI has no :CHANnel<n>:IMPedance yet), the 0 V stretch after the trigger point at 50 ms/div, extra counts of the counter on an MHO934.

Everything else as in mho-dev-36. Install as before; the recordings stay in /oos.

File What
oos-mho900-dev-42.img the OOS image, for the install on a second card (boot/card-install.py, then boot/switch.py oos)
oos-mho900-dev-42.oosupd the same image as a signed package, for the install over ADB (oos-update gel-install)
oos-update-mho-dev-42 the install tool of this build, for the scope (aarch64)
mho-setup.py, mho-poll the set-up in three steps: record under the stock system, install under OOS, report afterwards (docs/mho.md "Setting a unit up")
mho-check.py, mho-settings.py the recording tools mho-setup.py record runs
MHO900_OOS_Install.GEL the stick install. Not known whether the stock MHO900 update accepts it. Use the ADB or card route
SHA256SUMS checksums

Built from tag mho-dev-42 (build 20261124-113245) with kernel/build-base.sh (Linux 6.12.115; the kernel of mho-dev-35) and OOS_BOARD=mho boot/build-dev-image.sh. Sources: this tag, and the third-party sources of v0.1.14.