Repository navigation
mho-dev-48: the sweep (Auto/Normal/Single) reaches the board (MHO900 test build)
Pre-releaseSuperseded by mho-dev-49.
Development build for testing on an MHO900. Not a release. Built from the branch oos-mho: the fixes from hp197's tests of mho-dev-35 and -37 and his pull requests #561 and #562 (issue #4). Please test carefully and report back with oos-mho-report (or mho-setup.py <scope-ip> report).
Verified on hp197's MHO98 (mho-dev-35): fan, counter, peak detect's picture, 50 and 100 ms/div with the edge at the trigger point, roll, the generator board found, generator 1's offset.
Fixed in this build, not yet verified on hardware:
- Generator offset: changing a channel's setting no longer resets generator 1's offset to 0 V (found by hp197).
- Sweep: Auto, Normal and Single now reach the board (OOS kept the auto trigger on whatever the screen said). With Normal, a single waits for its edge, and the frames triggered on the falling edge should stop; with Auto they may still come when no edge arrives in time. Until confirmed, OOS still drops such frames.
- The SCU mode word 0x4008 carries the record's interleave factor (dev-47).
- 50 and 100 ms/div: the recording took them in roll mode; OOS now makes them ordinary records with the trigger in the middle. Verified on hp197's MHO98: the 0 V stretch is gone.
- Logic analyser: its sample rate is now set (a quarter of the analog rate, measured by hp197 under the stock system), and its words get the matching time axis. The log still shows what the LA words hold every 50 frames.
- The empty start of some frames at 50 to 200 µs/div (Normal and peak detect): frames where the board triggered away from the trigger point are no longer shown. The log counts them, to find the cause.
- 50 ms/div: the 0 V stretch after the trigger point is not fixed yet; the log now says where the record holds one word for long.
- The generator's shape DC no longer crashes the screen.
- Peak detect: the measurements no longer count twice the frequency.
- Memory depth: a fixed depth takes the nearest rate the unit's recording has (it stayed at 10 k before).
- Generator 1 puts out every shape: sine, square, ramp (with its symmetry), pulse (with its duty), arbitrary, noise and DC, also after a start by OOS (the output's scale words are set now, #562). Verified on hp197's MHO98: sine, square, ramp, pulse, noise and DC at the right amplitude and frequency. Up to 2 Vpp, ±1 V offset.
- Bode with the built-in generator: verified on hp197's MHO98 through a cable (flat within +0.14/−0.05 dB from 100 Hz to 1 MHz).
Still open: the logic analyser on a unit (not yet tried with this build), 50 Ω (set it on the screen: OOS's SCPI has no :CHANnel<n>:IMPedance yet), extra counts of the counter on an MHO934.
Everything else as in mho-dev-36. Install as before; the recordings stay in /oos.
| File | What |
|---|---|
oos-mho900-dev-48.img |
the OOS image, for the install on a second card (boot/card-install.py, then boot/switch.py oos) |
oos-mho900-dev-48.oosupd |
the same image as a signed package, for the install over ADB (oos-update gel-install) |
oos-update-mho-dev-48 |
the install tool of this build, for the scope (aarch64) |
mho-setup.py, mho-poll |
the set-up in three steps: record under the stock system, install under OOS, report afterwards (docs/mho.md "Setting a unit up") |
mho-check.py, mho-settings.py |
the recording tools mho-setup.py record runs |
MHO900_OOS_Install.GEL |
the stick install. Not known whether the stock MHO900 update accepts it. Use the ADB or card route |
SHA256SUMS |
checksums |
Built from tag mho-dev-48 (build 20261124-151300) with kernel/build-base.sh (Linux 6.12.115; the kernel of mho-dev-35) and OOS_BOARD=mho boot/build-dev-image.sh. Sources: this tag, and the third-party sources of v0.1.14.