🚀 GMiner 1.35 — Firmware and Toolkit Update
- Autotuning: reworked hot-chip tuning on BM1368-based devices, including S21, T21, S19 XP+, and Hydro models using these chips. The temperature target is calculated across all hashboards; frequency adjustments also run during voltage tuning.
- Liquid cooling: added coolant temperature readings and temperature differences for each hashboard. The dashboard now features a unified cooling widget, along with coolant and maximum board temperature charts.
- Hashrate monitoring: low-hashrate checks now begin after the first 30 minutes of continuous mining to avoid premature warnings after startup.
- Diagnostics: logs now include detected hashboard details, chip numbers in temperature error messages, and warnings about communication delays with the PSU and hashboard controllers.
- Toolkit: added batch processing with configurable batch size and pauses between batches.
- Default settings: BM1368-based devices now use built-in chip temperature sensors and enable hot-chip tuning by default. The default critical temperature limit for Hydro models is 80°C. These defaults apply when settings are created or reset; explicitly saved values are preserved during updates.