Highlights
- New repairs for wrong value scales: BattMind now warns when a power sensor without a unit looks like kW, when the battery level looks like a share (0–1) instead of a percentage, and when a price sensor is in a subunit, per MWh or per Wh
- New repair for a frozen house consumption sensor: raised when the sensor has shown the same value for 6 hours
- Better Test my automation: Discharge allowed can now be proven after a sale, and Stop battery with no steps gets a clearer explanation
🔧 Improvements
- Value scale repairs: these only inform, they change nothing and convert nothing, because your own automation may read the same sensor.
- Power sensors without a unit: a power sensor without a unit is read in W. The repair is raised when its values over the last 3 days stay at 50 or below with decimals, which looks like kW.
- The battery level looks like a share: raised when every battery level value of the last 3 days is between 0 and 1 with decimals (0.85 would be read as 0.85 %, not 85 %).
- Prices in a subunit, per MWh or per Wh: judged by the price sensor's unit only. The prices would be 100 or 1000 times too large or too small.
- House consumption sensor shows the same value: the repair names the sensor, the value and since when. It appears 6 to 7 hours after the last change and goes away when the sensor shows another number. A restart keeps the repair and its time. Only the house consumption sensor is checked. If the value really stays the same, ignore the repair.
- Missing sensors repair: a sensor that is enabled and in the entity registry is no longer counted as missing when its state is unavailable or unknown. Two minutes after each start, BattMind lists configured sensors that are still unavailable in a persistent notification. A house consumption sensor that stays unavailable also gets a persistent notification.
- Test my automation, Discharge allowed: the step is now also proven when the battery was still selling just before (after Forced discharge, if Stop battery did not stop it). The sale must end and the battery must feed the house. If most of the sale continues, the step fails with a message that the forced discharge was not ended (check for a missing
stop_forcible_chargeor a forced mode that runs for a set time). A battery that only gives a little more than the house uses after the sale ends is shown as not proven. - Test my automation, Stop battery: when your automation has no steps for it, the result now explains that BattMind only sends it as a safety stop for a battery temperature that is too high, too low or unknown. With a temperature sensor chosen it warns that your automation does not stop the battery. Without one it says no steps are needed.
- Texts and translations (Danish, German, English, Polish, Ukrainian) were updated for the new messages.
What's Changed