Repository navigation
SmartEVSE v3.11.3 Release Notes
WARNING:
If you have sub-panel configuration, your EVMeter was used to guard MaxCircuit. Since version v3.11.0 a separate CircuitMeter can be defined, and THAT meter is used to guard MaxCircuit. EVMeter then will be used what it was intended for, to measure the number of kWh that goes into your EV.
So if you have sub-panel (garage-) configuration, reconfigure your current EVMeter to the new CircuitMeter!!
IF YOU DONT CHANGE THIS YOUR MAXCIRCUIT WILL NO LONGER BE GUARDED!!!
Improvements:
- platformio.ini: upgrade espressif to 7.1.3; the wifi-library update improves connectivity on OCPP
- Add MQTT announcements for circuit energy metrics (#400)
BugFixes:
- esp32.cpp: only publish EVMeter Energies when not zero
- glcd: show network related menu options for both WiFi and Ethernet
- network_common.cpp: Add WiFi network scanning to portal.
- get timezone from browser when serving index.html
- glcd.cpp: clear all error flags. write settings immediately to nvs when exiting LCD menu.
- fix comma-operator misparse in Update.begin() calls
- Fix undefined mainsHost variable crashing WebUI for HomeWizard mains meters (#393)
- esp32.cpp: change auto update url to SmartEVSE_firmware