Skip to content

v2.0.0

Latest

Choose a tag to compare

@rjvh00001 rjvh00001 released this 29 Oct 10:14
52460ba

Architecture

  • Main loop refactored into separate state machines: a top-level MachineController coordinates commissioning, ready, sleep and error states.
  • Model detection (diyPresso One / Two) in hardware management.

diyPresso Two support

  • Support for the steam group: thermoblock, steam pump, steam switch and steam heater control.
  • Steam PID uses separate gains and its own integration band while the pump runs. The integral resets when the pump stops.
  • New steamFF (feedforward) setting. Tuned steam defaults (integration band 5, iDownFactor 3).
  • The auto-sleep timer resets on the steam button and while steaming.

Boiler PID

  • Wider integral clamp and conditional integration. D is left out of the saturation check.
  • Faster integral unwind above setpoint (iDownFactor).
  • The integral is held during shot recovery (BrewIntegralHold FSM, starting at the dip) and while the PID output is not used. It resets while not in control.
  • New dffDecay setting and settings for the PID windup limits. Fixes ffHeat/ffReady not being applied immediately.
  • Tuned boiler PID defaults.

Settings menu

  • Two-level settings menu. All settings are defined in one list (dp_settings_list.h).
  • Each submenu can be reset to its defaults, with a two-line confirmation.
  • Descriptions for the menu settings (menu_settings.md) and an updated serial command overview.
  • New encoderReverse setting to reverse the rotary encoder direction.
  • "Pump band" renamed to "Pump I band". FF menu items renamed to "Feedforward".

Display and other fixes

  • Updated logo screen at startup
  • Fix: the reservoir level indicator no longer disappears near full. The weight value moved to the right.
  • Fixes to the MQTT and WiFi functionality