[1.3.0b8] - 2026-08-13

Fixed

  • Dynamic Pricing intraday remaining-consumption forecasts could be inflated by morning demand (#263): manual, pre-slot and evening reevaluations extrapolated the consumption rate observed since midnight across every hour left in the day, so an already-finished overnight or morning peak could turn a 17.98 kWh daily average into a 40.61 kWh remaining forecast. Reevaluations now compare the unspent seven-day average with its normal time-prorated remainder and use the same windowed, excluded-load-adjusted accumulator as the historical data. Notifications and diagnostics distinguish the remaining consumption and solar from their full-day forecasts.
  • Solar forecasts could receive a hidden 15% reduction outside the scheduled daily evaluation: intraday and startup reevaluations, Solar Charge Delay and Smart Pre-discharge multiplied the configured forecast sensor by 0.85, so a 4.03 kWh forecast appeared as 3.43 kWh and predictive decisions could then penalize it again through the user-configurable margins. All paths now use the sensor value unchanged; actual production is still subtracted when calculating the energy remaining, while predictive-charging conservatism remains explicitly controlled by the Solar Forecast Safety Margin and Predictive Grid Charge Margin settings.