Repository navigation
Releases
Releases · g-lok/chirashi
v1.8.0 - Info & Dry Run Modes
v1.7.1 - Cue Accuracy & REX2 Refinement
Fixes critical cue marker drift and over-slicing bugs in REX2 and resampled WAV conversions.
v1.7.0
v1.7.0 - New Formats: Bitwig Multisample, SP-404 MKII, MPC PGM, Reaso…
v1.6.0
v1.6.0 - Recursive preservation by default & --flatten
v1.5.0 — The Precision & Vintage Update
Added
- Vintage Sampler Support:
- Yamaha TX16W: Read and write support for
.w01...w32and.txwformats (12-bit packed mono PCM, Typhoon OS). - Amiga IFF 8SVX/16SV: Read and write support for classic Amiga 8-bit and 16-bit mono formats.
- ProTracker MOD: Added input reader for extracting 8-bit samples directly from tracker modules.
- Yamaha TX16W: Read and write support for
- WAVE_FORMAT_EXTENSIBLE Support: Full support for reading high-precision and multi-channel WAV files using the
65534(0xFFFE) format tag. - IEEE Float Decoding: Support for decoding 32-bit and 64-bit IEEE Float WAV files.
- Improved WAV Parser: Standardized WAV parsing across all reader modules (XRNI, OT, DT2PST, OP-XY).
Fixed
- XRNI WAV Compatibility: Refactored XRNI reader to support all WAV subtypes (PCM, Float, Extensible) embedded in
.xrnicontainers. - OT Companion WAV Support: Enhanced Octatrack companion WAV detection to handle extensible and floating-point formats.
v1.4.3 - Version Sync Release
Fixed
- Version Parity: Synchronized hardcoded version strings and build flags to ensure
--versioncorrectly reportsv1.4.3across all platforms.
v1.4.2 - Strict Parity & Metadata Sync
Fixed
- REX2 Strict Slicing: Defaulted REX2 decoding to 'Strict' mode, treating every marker in the SLCE table as a hard slice. This ensures parity with Ableton Simpler and hardware samplers (like M8) that ignore internal transient sensitivity.
- OP-1 Category: Corrected default folder name to
chirashi(8 chars) to fit the 10-character hardware limit. - Dynamic Metadata: Replaced remaining
REXConverterbranding artifacts with the actual source filename in PTI, OP-1, and EL encoders.
Added
- --rex-sensitivity flag: Re-enables the 'smart' adaptive transient filtering based on analysis sensitivity for REX2 files.
v1.4.1 - Patch: Hardware Compliance
Fixed
- Hardware Compliance: Changed default
--categoryvalue fromchirashi-slicedtochirashito ensure compatibility with the 10-character folder name limit on OP-1 hardware.
v1.4.0 - Metadata & Categorization Update
Added
- --category / -c flag: Overrides the organizational folder name for hardware samplers (e.g., OP-1). Defaults to
chirashi-sliced. - Dynamic Metadata: All instrument formats (PTI, OP-1, EL) now use the source filename for internal instrument names instead of legacy strings.
Fixed
- Artifact Cleanup: Removed remaining hardcoded naming artifacts across all encoders.
v1.3.1 - Patch Release
Fixed
- DT2 Encoder: Removed hardcoded naming artifact in Digitakt II binary presets.