Bug fixes
get_cpu_state() now reads the CPU's operating state from SZL 0x0424, in both clients. Previously it sent a read
request with no address and returned "S7CpuStatusRun" whatever the PLC answered. Startup, HOLD and DEFECT are
reported as "S7CpuStatusStop", as native Snap7 does. A PLC that refuses SZL 0x0424 now raises S7ProtocolError;
the heartbeat of the synchronous client counts such a refusal as a live connection. Not yet tested on hardware (#988).
The server answers SZL 0x0424 from its CPU state, and refuses a read request that has no address specification.
Previously it answered such a request with the first four bytes of DB1 (#988).
read_tags and read_multi_vars with a list of dicts now accept more than 20 items, in both clients. Previously
they raised ValueError over MAX_VARS, although the read optimizer already splits a read over several requests.
The optimizer now also puts at most 20 items in one request; optimizer.packetize takes a max_items argument
for this. The ctypes form of read_multi_vars and write_multi_vars keep the limit (#989).
read_tags now raises NotImplementedError for a symbolic tag, as read_tag does, in both clients (#989).