Data-layer fixes found by an audit of what physioex reads against the raw files of every dataset. Label caches of
Sleep-EDF, WSC and Alzheimers are recomputed on first use (LABELS_REVISION 2, 2 and 3). Cached WSC events are not
versioned: delete events/<subject>.json of the 26 allscore nights whose events changed.
Fixed
- WSC
.allscore.txt: labels and events are anchored atSTART RECORDING. ASTAGE - NO STAGEline timed before it
moved the time origin back by hours and shifted every later label (45 of 743 files). Midnight is a backward jump of
the clock,PAUSEDtoRECORDING RESUMEDstretches are removed (the EDF has no samples there), and labels or events
past the end of the EDF are dropped. A file withoutSTART RECORDINGyields no labels, as before. - Sleep-EDF: the hypnogram always runs to 24 h; its tail is cut at the end of the PSG instead of being paired with
zero padding (in one night 614 epochs ofWake). - Alzheimers: labels past the end of a truncated EDF are dropped.
- MESA:
*_Offelectrode-status flags (1 Hz) are classifiedOTHER, not EEG/EOG/EMG.
Added
- WSC events from
.sco.txt(the 1827 Gamma-system nights; only the 743 Twin-system.allscore.txtnights had
events). Same event types as the allscore parser.Scan # x2counts samples at twice the EDF rate; a few files write
the scan with two extra digits (the clock column is used) and 548 write the length ×100 with a negative sign.