You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Frames and coordinates. Rotating frames, mirror symmetry (half, quadrant and octant
boxes), comoving coordinates for cosmology, the shearing box, and axisymmetric (R, z) and
spherical (r, θ) grids, each on the uniform grid and the adaptive mesh.
Radiation transport. Two-moment (M1) transport with a reduced speed of light chosen cell
by cell, on the uniform grid and the adaptive mesh, with a light curve in the Diagnostics
panel and presets for a clump's shadow, radiative shocks and a star held up partly by
radiation.
Nearly incompressible flow. A weakly compressible liquid, and implicit pressure for the
liquid and the ideal gas: steps set by the flow speed instead of the sound speed, with
self-gravity, uniform fields, point masses, species, obstacles and inlets, on both grids.
Equations of state. Hydrogen and helium with molecules, dissociation and ionization from
a table of one free energy; ANEOS rock, iron and water, with planets built from them and a
Moon-forming impact preset.
Stars. A point-mass core (a giant), with a common-envelope preset and example setup;
presets with the hydrogen and helium equation of state (a tidal disruption, a common
envelope, interstellar gas).
The page and the API. A setup preview where shapes are clicked, dragged and turned;
field brushes and field-line tubes; session logs with exact replay; screenshots at the grid's
own resolution; a gallery of the presets in the README.
Releases have a changelog: this file, in the npm package and as the notes of each GitHub
release.
Changed
Self-gravity conserves energy better and costs less. The Poisson solve starts from the
potential extrapolated in time and takes one V-cycle a step on the uniform grid instead of
two (about 10% faster per step at 128³), and the gravitational work is moved to the mean of
the old and new potentials after each solve. The Evrard collapse at 64³ now drifts 0.23% in
total energy (0.82% before).
Implicit pressure is time-centered where the step resolves sound, on both grids, at the
same one solve a step: a resolved sound wave keeps 98% of its amplitude over a period (86%
before), and a shock tube's error falls by 40%.
Per-block timesteps: a run starts with 16 single steps before its first cycle, and the
half-step potential of each block follows the potential's curvature in time (the Evrard
collapse loses no more energy with per-block steps than with one timestep).
Fixed
Adaptive mesh: cells created by refinement in cold, fast gas got an internal energy many
orders of magnitude too large (a Zel'dovich pancake on blocks was off by 6.5% in density,
now 0.7%, as on the uniform grid).
Adaptive mesh: the potential's boundary values at the edges and corners of refined regions
were first order, so the error grew with each level added (a uniform sphere on three levels:
0.26%, now 0.05%).
Implicit pressure: species in a liquid lost 0.2% of their mass over a run; they are now
carried on the whole step's mass fluxes and conserved to round-off.
Diffusion: a face takes the smaller of its two cells' densities, so thin gas beside dense gas
no longer blows up.
Species that set the equation of state no longer raise a WebGPU validation error on the
uniform grid.
Restarts resume at the step they were saved at.
Headless runs and the GPU test suite no longer wait forever at their end on macOS, where
Chrome's crash handler could outlive Chrome and hold the browser's close.