v0.9.95 — A Home Assistant that stays responsive, humid nights handled, vacation that stays vacation, your thermostat changes respected, and Climate Advisor in your language
Pre-releaseThis is the first release since v0.9.41: 51 builds with 56 bug fixes and 20 new features. Its theme is a Home Assistant that stays responsive, even on a Raspberry Pi, together with humid nights handled properly, your own thermostat changes respected, a forecast you can trust and Climate Advisor in your language.
Highlights
- No more Home Assistant freezes while Climate Advisor learns, and much shorter hold-ups in its everyday work. Its long learning runs in a separate process, its larger files are saved and loaded in small steps, and the Status chart reads only the days it shows. Thanks to Jeffrey Sica (@jeefy) for the freeze report, the diagnosis and the first implementation. (#1722, #1730, #1727, #1331)
- A responsiveness check. The Debug card shows how late Home Assistant runs and what Climate Advisor's own work costs, and one log warning says if Home Assistant keeps running late and whether Climate Advisor is the likely cause. (#1730)
- Humid nights keep the moisture out. The fan, natural ventilation, the blower and open-window advice hold off when the outside air is humid, and the optional Humid Overcool dries a sticky house. (#1691, #1692, #1694, #1695)
- Vacation and guest switches that glitch no longer end your vacation. A home, vacation or guest switch shared with HomeKit or another system that drops out or flickers for a moment is ignored, so no false "Welcome home!" and no return to comfort temperatures while you're away. (#1739)
- Your thermostat changes stick, your newest change gets its own hold, and switching automation off puts your own setting back. (#1603, #1712, #1711)
- Window and fan advice you can rely on: suggestions weighed over the next 3 days instead of a whole week's forecast, ventilation that waits for the fan, window cooling that keeps running, and fan notices that keep coming with automation off. (#1734, #1605, #1705, #1718, #1720)
- A more accurate forecast on the chart and in the night plan, quieter nights without false comfort incidents, and a thermostat that misreads after a furnace trip is caught. (#1593, #1678, #1676)
- Heat-only and cool-only homes are handled as what they are, with new outdoor lockouts. (#1699, #1715)
- Use your own AI provider, and AI reports that name the day, say what really happened and write in your language. (#1336, #1674, #1596, #1657)
- Traditional Chinese (Taiwan) as the 17th language, no English codes left inside your language, and every setting explained in one place. (#1656, #1659, #1671)
- Gold on Home Assistant's quality scale (self-assessed), and over 95 % test coverage in every part. (#1637)
Before you upgrade
Settings
- New: Humid-Air Guard (Settings → Sensors & Fan), on by default, also for existing installs, with a dew point ceiling of 65 °F (55-70 °F; shown in °C on a Celsius install). On a humid night your whole-house fan or blower may stay off and open-window advice is withheld where it used to start. Only turning the guard off restores the old behaviour. (#1691, #1692)
- New: Humid Overcool (Settings → Learning & Behavior), off by default. Nothing changes until you turn it on; the learning suggestion only tells you about it. (#1694, #1695)
- New: Recalibration Guard (Options → Temperature Sources), on by default. It only acts when the room reading comes from the thermostat. Turn it off to get exactly the earlier behaviour. (#1676)
- New lockout options (Temperature Setpoints): No cooling below outdoor, No heating above outdoor, both off by default. A command the thermostat doesn't offer is now skipped quietly instead of reported as a failure. (#1699)
- One setting is renamed: Heating and cooling season is now Heating and cooling allowed. Your saved choice is kept and works exactly as before. Automations that read its stored value (
auto,heat_only,cool_only) are unaffected. (#1715) - HVAC Fan Restriction "Heat only" now waits the 2 hours after cooling only while the indoor dew point is 55 °F or more; without an indoor humidity reading it works exactly as before. (#1693)
- AI settings now cover the whole install, not each zone. On upgrade, the settings of the first zone with AI turned on are used everywhere; if zones differed, each zone's old values are kept in a backup and a Repairs notice says whose were kept. Reasoning effort offers Low and Medium only (a saved High becomes Medium). (#1336)
- Built-in Claude is deprecated. Pasting a Claude API key still works, but it will be removed in a later release, and a Repairs notice reminds you while it is in use. To move: add Home Assistant's Anthropic integration with an AI Task entity, untick Recommended model settings, set max tokens to at least 8192 (the default is 3000), and choose that entity in Climate Advisor's AI settings. (#1336)
Behaviour you may notice
- Home/away, vacation and guest switches take effect about a minute after they change. A switch that flips back inside that minute changes nothing, and one that shows "unavailable" or "unknown" keeps its last on or off value. Coming home or leaving is acted on a minute later than before, and the 15-minute away timer starts after that minute. (#1739)
- Bedroom-sensor installs: switching automation off, or removing, disabling or reloading the zone, now writes your plain setpoint once instead of leaving the bedroom-sensor adjustment on the thermostat. (#1711)
- Switching the thermostat Off doesn't stop window cooling's blower (the same as natural ventilation); turn the fan off to stop it. (#1705)
- Fewer comfort incidents and violation minutes at night. The Comfort Score's violation minutes and the stall alert use the same rule as comfort incidents, so they drop on nights the bedroom loop is working. (#1678)
- Window suggestions are weighed over the next 3 days. In testing, fewer than 1 in 200 plans differ in the next two days, and only with the newer prediction model. (#1734)
- The forecast fixes change what you see on the chart, in the night plan and on the Prediction accuracy page. Decisions read v4's curve of the house drifting with no heating or cooling, which these fixes don't change.
Sensors and automations
- Last Action Time and Next Automation Time are now timestamp sensors. Cards show them as "5 minutes ago" or "in 2 hours" in your language, and automations can trigger on them. Their state text changes: Last Action Time is now in UTC (
2026-11-20T14:00:00+00:00), and Next Automation Time was a clock label like6:30 AMand is now a timestamp, orunknownwhen nothing is scheduled. A template that prints or compares the old text needs updating, for example{{ as_timestamp(states('sensor.climate_advisor_next_automation_time')) | timestamp_custom('%-I:%M %p') }}. (#1648) - Indoor/Outdoor Temperature and Forecast High/Low go unavailable while their source is down. An automation that reads them during an outage sees
unavailableinstead of an old value. (#1642) - Two learning suggestions are gone: "frequent door/window pauses" and "comfort misses". An automation that calls
climate_advisor.respond_to_suggestionwith those keys now gets an "unknown suggestion" error.acceptstill works for the others, as an acknowledgement. (#1652)
Under the hood
- Climate Advisor starts a short-lived helper process (Home Assistant's own Python) for its long learning work. It runs only Climate Advisor's own code, writes no files, gets no tokens or passwords from Home Assistant's environment, and is stopped when Climate Advisor reloads or Home Assistant restarts. If your system can't start one, Climate Advisor logs one warning and works as before. At most one fewer of these runs at once than your machine has cores: nothing changes on a Raspberry Pi 4, and on a 2-core board a learning job can wait its turn. (#1722, #1730)
- Larger history files are written one entry per line. They are still plain JSON. (#1730)
- The learned forecast model stores a little more: the longest heating or cooling run your thermostat usually makes (learned at the next daily refit; until then the forecast works as before), and when the last fit was attempted. (#1594, #1722)
- Daily learning records gain one field (humid cooling minutes); older records read 0.
- The config entry moves to version 21. Downgrading is not supported.
What you'll notice
Home Assistant stays responsive
Home Assistant stays responsive while Climate Advisor learns (#1722)
- Before: on a Raspberry Pi 4 the forecast model's fit ran inside Home Assistant and froze it for 60-100 seconds: the UI stopped answering, Supervisor missed its watchdog, a ConBee Zigbee stick reset, and Climate Advisor then raised "entity not responding" alerts for the sensors it had just starved. It happened after every restart and every 6 hours during the first 3 days, and every night after that, when the night check runs about ten fits.
- Now: that work, and the heating and cooling rate refit, run in a separate low-priority process. In testing, Home Assistant stayed as responsive during a fit as when idle, instead of slowing to about a thousandth of that, and what Climate Advisor learns is identical. A stuck helper is stopped after a time limit, and a reload or restart stops it at once.
- Less work at the start: during the first 3 days, when the fit can't produce a model yet, it no longer runs at all (a few hundredths of a second instead of a minute or more on a Pi). A restart within 6 hours of the last attempt no longer starts one again straight away.
Shorter hold-ups in everyday work (#1730, #1727)
- Before: saving or loading a large history file held up Home Assistant in one long stretch: 84-230 ms on a desktop, roughly 0.4-1.4 s on a Pi. The Status page's prediction chart took about a second to build, because it scanned the whole forecast-accuracy archive once per sensor and per forecast lead.
- Now: files are written and read one entry at a time, so no single hold is longer than a few milliseconds. The chart reads only the days it shows: the 24 h view takes about 40 ms instead of a second, and a year's view about a quarter of the time it did. The plan for the coming days builds about four times faster, and the nightly learning's preparation many times faster.
- Unchanged: every plan, chart and learned value is identical to before, checked against the previous version on thousands of cases.
A smoother Home Assistant (#1331, #1598, #1599)
- Diagnostics, logs and the AI Investigator no longer briefly freeze Home Assistant while the control-quality report is built; it is now built in the background.
- The 30-minute cycle no longer scans a whole year of chart history; charts and diagnostics read only the days they need.
- The hourly trim of old chart history no longer briefly pauses Home Assistant, even with a full year of history.
Climate Advisor watches how responsive Home Assistant is (#1730)
- The Debug card has a new Performance group: how late Home Assistant's event loop runs (checked every second), how long the plan build takes, and Climate Advisor's most expensive background jobs.
- If Home Assistant runs late in 10 of the last 60 minutes, Climate Advisor writes one warning to the log. It names Climate Advisor's own work as the likely cause only when that work lines up with the late minutes; otherwise it says the delay probably comes from elsewhere (another integration, the recorder, a backup). One line follows when things are back to normal, and a reminder if it lasts a day. Climate Advisor's own routine work on a slow machine never triggers it by itself.
Lighter nightly learning (#1726)
- Each night the forecast model starts from the previous night's, and it also tried a second search from scratch that almost never found anything better. That second search now runs only when it can matter: when the night's learning did not settle, or moved the model noticeably. It uses about a quarter to a third less processor time, and forecasts stay as accurate.
Humidity
Humid nights keep the moisture out (#1691, #1692)
- Before: on a muggy night the whole-house fan, natural ventilation or the HVAC blower could pull wet outdoor air into the house, and Climate Advisor could suggest opening the windows.
- Now: with the new Humid-Air Guard (on by default), when the outdoor dew point is 65 °F or more (adjustable), or the outside air is humid and wetter than the house, none of them starts and the advice says "Keep windows closed for now". If windows are already open you get one notice to close them so the AC can take over.
Humid Overcool (optional, off by default) (#1694, #1695)
- On a muggy day the AC's short runs cool the room but leave it sticky. With Humid Overcool on, while the AC is already cooling and the house is humid, the cool setting goes 1-2 °F lower for at most 60 minutes per humid spell, so the run lasts long enough to dry the air. A learning card suggests it when your house would benefit.
The blower waits after cooling only when it matters (#1693)
- With HVAC Fan Restriction "Heat only", the 2-hour wait after cooling now applies only while the house is humid. A dry house gets its blower straight away.
Dew point in the briefing, and humidity readings you can trust (#1696, #1690, #1709, #1689)
- The briefing shows dew point indoors and out, and says when humidity changed a decision.
- Reconnect glitches, stale sensors and wrong units are ignored, and a humidity-only outdoor sensor falls back to your weather service. A false 32 °F outdoor reading after an outage is no longer taken as real.
Fresh air, windows and fans
Window suggestions look 3 days ahead (#1734)
- Before: whether to suggest opening the windows today was judged over the whole forecast, up to a week. With the newer prediction model, the house's stored heat carries a window's effect for days, so today's suggestion could hinge on the forecast for 5 to 7 days out, which is only daily highs and lows.
- Now: it is judged over the next 3 days, or until a day after the windows would close if that is later. In testing, the next two days' suggestions differed in 0.03-0.43% of plans with the newer model and never with the older one. The plan still covers the whole forecast, and builds about a third faster.
Ventilation that waits for the fan (#1605)
- When ventilation cools the house to the comfort floor but the fan can't be switched off yet (the 5-minute toggle limit), Climate Advisor now waits: it doesn't restore heating or cooling, or start a grace period, while the fan still runs. Comfort is restored once the fan stops, and the Activity Report says the fan-off is deferred.
Window cooling with the HVAC blower keeps running (#1705)
- It used to turn itself off about 5 minutes in. Bedtime and wake-up now wrap it up properly.
Fan notices with automation off (#1718, #1720)
- Before: with automation off, the fan and the heat both running and the house closed up, you were told once. If you then opened a window for a few minutes and closed it again, the second closed-up spell went unannounced, and the fan could run for hours on the sealed house. Separately, after one "fan and heat running together" notice, switching automation on and off again silenced that notice for next time.
- Now: each new episode gets its notice. With automation on, nothing changes: Climate Advisor still stops the fan within seconds.
Your thermostat and your changes
Vacation that stays vacation (#1739)
- Before: a vacation or guest switch shared with HomeKit (or any other system) could drop to "unavailable" or flicker off and on for a moment. Climate Advisor read that as "off", ended the vacation, put your comfort temperatures back, sent "🏠 Welcome home!", and applied the setback again when the switch came back.
- Now: a switch that reads "unavailable" or "unknown" keeps its last real value (a warning is still logged), and a change only counts once it has held for about a minute. After a restart on the same day, a vacation switch that hasn't reported yet keeps the vacation you were on.
Your thermostat changes are respected (#1603, #1612, #1613)
- A mode change right after one of Climate Advisor's commands (its regular setpoint update, a blower cycle, the whole-house fan starting) is now noticed a few seconds later and kept as your manual override. Before, it was missed and the house went back to Climate Advisor's plan.
- After you confirm Off as a manual override, turning the thermostat to Cool or Heat while Climate Advisor is sending a command of its own is no longer ignored. The dashboard no longer shows "manual override: off" over a house that is cooling or heating, and your Heat choice is no longer reverted when the old Off grace ends.
- These are also seen as yours instead of being undone at the next update: turning the heat or AC back on right after Climate Advisor pauses it for an open door or window; changing the setpoint right after its regular setpoint update; turning the blower on just after that update.
- What isn't read as your change: a thermostat that switches itself to fan-only, or restores its own program setpoint, in answer to Climate Advisor's fan command.
Your newest temperature change is kept (#1712)
- Before: you set 69 °F and Climate Advisor held it. Later you changed it again (say to 67 or 70 °F). The second change was ignored: the Activity log didn't show it, and when the first hold ran out the schedule went back over it, sometimes minutes after you set it.
- Now: your newest temperature gets its own full hold. A change made inside the 10-minute confirmation is recorded too and confirms from your newest setting.
Switching automation back on (#1624)
- If you had the whole-house fan running and set the heat or AC while automation was off, Climate Advisor turning the heat or AC Off when you switch automation back on is no longer reported as "Climate Advisor changed your thermostat setting". Nothing it does in the house changes.
Heat-only and cool-only homes (#1699, #1544, #1488, #1542, #1715)
- New outdoor lockouts ("No cooling below outdoor", "No heating above outdoor") and the setting Heating and cooling allowed (Heating and cooling as needed / Heating only / Cooling only; it used to be called Heating and cooling season) are described only by what they can do: no promised AC, pre-cool or false comfort failures.
Switching automation off puts your own setting back (#1711)
- Switching automation off, or removing or reloading a zone, writes your plain setpoint once, including undoing the bedroom-sensor adjustment.
Cloud thermostats that answer late (#1272, #1595)
- No repeated setpoint: a fan turning on or off right after a setpoint change no longer makes Climate Advisor send the same setpoint again. It waits up to 3 minutes for the thermostat to answer. A thermostat that really reverts to a different value is still corrected 30 seconds after the fan command.
- No false "HVAC mode not applied": a mode change the thermostat reports 2–3 minutes late is no longer flagged. A thermostat that really ignores the mode is still reported, about 3 minutes after the change.
A thermostat that misreads after a furnace trip (#1676)
- Before: when the furnace overheated and its high-limit safety shut it off, the Ecobee read 75-76 °F for 10-40 minutes while the house was 68-69 °F. Climate Advisor believed it. It flipped between the thermostat's two readings, judged heating against a room that wasn't warm, learned from the false readings, and the AI report couldn't explain it.
- Now: a jump of 2.5 °F or more within minutes of the heating stopping is recognised as recalibration, because a real room never warms that fast. Climate Advisor logs a warning every time and shows a Repairs notice once; ignore it to silence it. Until the reading settles, it reads the room from your sleep sensor or a dedicated indoor sensor, then switches back, and the status card says so. With no other sensor it only warns. Those readings stay out of learning.
- Checked against real history: over nine days the rule caught all 10 episodes and nothing else.
Forecasts, nights and comfort
A more accurate forecast on the chart and in the night plan (#1593, #1609, #1610, #1616, #1620, #1594)
- The bedroom at night follows how the bedroom loop really works: it remembers a setpoint raise already in force, counts short furnace runs as short and no longer shows a warm-up at bedtime. The night card's plan after bedtime starts from the live state.
- The thermostat in the forecast behaves like yours: it learns when your thermostat starts and stops heating against the setpoint it was actually given, so the forecast furnace no longer restarts too early. That includes a sleep-loop raise to the middle of a narrow band (for example 68 °F in a 66–70 °F band), which had made the night forecast run warm; cooling is fixed the same way.
- Forecast warm-ups are closer to the real ones where the thermostat or room sensor briefly reads the warm air of each furnace run. The forecast now ends a run at the longest run your thermostat usually makes. On one home's last 30 nights the average night error fell from 1.18 to 1.02 °F, and each forecast warm-up from 4.1 to 3.3 °F (real: 1.75 °F). Homes without that brief warm reading are unchanged (checked on 96 simulated homes).
- The sleep band and the awake band start on time: the forecast switches to the sleep band at bedtime instead of easing into it over two hours, uses the awake band from wake time, and follows your own setpoint while you have overridden the thermostat. The Prediction accuracy backtest scores the forecast the same way.
- Overall, the forecast for the next 1–24 hours is more accurate for the whole house, and much more accurate for the bedroom 12–24 hours ahead. The forecast's night warm-ups are still taller than the real ones; that makes the chart's bump look bigger but doesn't change how the house is run.
Quieter nights (#1678)
- Before: with a bedroom sensor, Climate Advisor logged 4-6 "house below your comfort range" incidents a night. Each one came about 5 minutes after it had already turned the heat on to warm the bedroom. One more came at wake-up while the house warmed to the day setting. The AI then reported the house as running cold and suggested raising the sleep floor.
- Now: the loop's own heat start and the first 30 minutes of the morning warm-up aren't incidents. Real problems still are: the loop at its limit, an open window or your own override, a stale sensor, the thermostat Off, or a furnace that never starts or can't catch up. Summer cooling gets the same treatment.
- Clearer wording: the "comfort kept" note gives the real distance below the range (1.6 °F, not 0.6 °F). Incident rows show one decimal, name the sensor, and show your target next to what the thermostat was set to.
Daylight-saving nights (#1244, #1607)
- Your change in the repeated 1 a.m. hour counts. On the night the clocks go back, a thermostat or fan change you make then is no longer mistaken for Climate Advisor's own command; it starts the manual-override grace as usual.
- Timers run for their real length around both changes: the 5-minute fan toggle floor, the natural-ventilation re-entry lockout, the welcome-home notice spacing and the fan stop when the indoor sensor goes offline. The Fan card shows the true stop time, and the daily comfort and away minutes can no longer go negative.
- Coast learning stays accurate. What Climate Advisor learns about how far your home keeps warming or cooling after the heat or AC stops no longer records weather drift as coast when the clocks go back, or loses that night's sample when they go forward.
A night-plan safeguard (#1670)
- If a night option were ever offered without its own label, planning the bedroom night would have failed for that evening. It now shows a generic label. No current option was affected.
AI and reports
Use your own AI provider (#1336)
- Pick it in AI settings: choose the provider's AI Task entity, or leave the field empty to use Home Assistant's preferred AI Task entity. Climate Advisor needs no API key of its own on this path.
- Set it up big enough: an output limit of at least 8192 tokens and medium reasoning. A provider whose context window holds both question and answer (Ollama) needs at least 24k; 32768 is suggested.
- Warned, never blocked: before an investigation runs, Climate Advisor checks the provider's limits where Home Assistant stores them. If they look too small, it says which setting to raise and offers Run anyway. If a report fails at the provider's limit or comes back cut short, you are told which setting to raise.
- What's different on this path: the report appears all at once instead of streaming, and there are no cost figures; your provider account is now the record of spending.
The AI Investigator writes in your language (#1657)
- Any Home Assistant language works, even ones Climate Advisor has no translation for (Swedish, Danish, Czech, Hebrew…). Regional variants are kept: Brazilian Portuguese is no longer generic Portuguese. The dashboard labels around the report stay English in those languages.
- It sees the project's known issues again, so a report can say "this is already tracked". A Home Assistant change had silently broken that. (#1650)
- It no longer tells you to run a developer script a HACS install doesn't have. (#1340)
AI reports that say which day (#1674)
- Before: a 7-day report listed "1:34 AM", "6:15 AM" with no date, so several mornings looked the same.
- Now: every time in a multi-day report carries its weekday and date, for example
Sat 11-21 6:15 AM. That covers the timeline, sessions, logs, correlations and the summary itself. The dashboard's Activity record shows the date too.
The Activity Report and AI say what really happened (#1596, #1267, #1268, #1597, #1606, #1269)
- A band that was never sent says so. At bedtime, wake-up and when you leave home, the row says "NOT sent" and why: the whole-house fan was running, the blower was ventilating through an open window, Climate Advisor was in test mode, or the thermostat rejected the command. The AI context says the same.
- Ventilation rows say what happened to the thermostat. When a window opens and ventilation starts, or ventilation restarts from a periodic re-check, the row says the thermostat was turned Off, or left alone and why, instead of "band-armed".
- When ventilation ends at the comfort floor, the row shows the mode Climate Advisor actually armed instead of the day's label. If nothing was armed it says "unchanged" and why: a window still open, your change kept, or the fan-off still pending.
- The AI no longer says Climate Advisor turns HVAC off on warm days. It knows the comfort band stays armed, and that heating or cooling starting inside it is normal.
Learning suggestions you can trust (#1652)
- Before: pressing Accept made the card go away while nothing in the house changed.
- Now: each suggestion says what you can do yourself, with Got it (hidden for 30 days) or Dismiss.
- Learning never changes your settings on its own: it will not lengthen your door/window pause or move your away temperatures.
Your language and your settings
Traditional Chinese (Taiwan) (#1656, #1636)
- If your Home Assistant is set to Traditional Chinese (
zh-Hant,zh-TW,zh-HK), Climate Advisor now speaks it everywhere: entity names and states, the setup and options wizard, services, Repairs, notifications, the daily briefing and the dashboard. Before, it fell back to English. - Written for Taiwan from the English, using Home Assistant's own Traditional Chinese wording, not converted from Simplified Chinese. A check keeps Simplified characters and mainland-only words out.
- Corrections are welcome: open an issue with the
translation: zh-Hantlabel.
Your language, all the way through (#1659, #1664, #1665)
- Notifications, the Activity Log and the dashboard no longer drop English codes such as "cooling", "hot" or "manual" into a translated sentence. HVAC modes, day types, sources, grades and fan speeds appear as words in your language. English reads exactly as before.
Settings named as they are (#1660, #1662, #1663)
- A cut-short AI report now tells you to raise Maximum Response Length in AI settings; before, it named a setting that no longer exists. The output-limit warnings no longer say
max_tokens in climate_advisor. - Every setting has the same name on the dashboard Settings tab as in Configure, in every language. On the classic dashboard, time settings show their unit after the value.
Every setting explained (#1671)
- Configuration options covers all 109 settings in the setup wizard and the options screens, grouped the way the Configure menu shows them: what each does, its default (°F and °C), its range, and when you might change it.
- Before: most settings were explained only by the short hint under each field.
- It stays complete: a test fails when a setting is added or renamed without its entry.
A setting that says what it does (#1715)
- Before: "Heating and cooling season" sounded like Climate Advisor followed the calendar.
- Now: "Heating and cooling allowed". The help text says your choice stays until you change it. With Heating only, Climate Advisor never switches to cooling and suggests windows or blinds on warm days instead; Cooling only is the reverse; a house far past its comfort range still gets the blocked side until it's back in range. The briefing, Status line, Activity and chart use the same words, for example "Cooling is off (you allowed heating only)".
Fixing things without starting over (#1643, #1646)
- A refused key or token asks for a new one: when Anthropic refuses the Claude key, or GitHub refuses the token, Home Assistant shows a "re-authentication required" card. Enter the new one and AI resumes at once. A refused key is no longer retried three times.
- Reconfigure a zone from its ⋮ menu to move it to a new thermostat, weather service or notify service, keeping its learning, history and settings. A thermostat another zone runs is refused.
Sensors, dashboard and Home Assistant fit
- Indoor/Outdoor Temperature and Forecast High/Low show unavailable while their thermostat, sensor or weather service is down, and come back with the next good reading. The Automation switch always stays available, so observe-only can be turned on.
- Last Action Time and Next Automation Time are timestamps (see Before you upgrade). AI Status, Day Type, Trend and Occupancy Mode list their possible states for the automation editor.
A clean restart (#1673)
- Before: after a restart on a multi-zone install, every zone but the first could build its first status, timeline, briefing and Activity Log text from raw codes such as
status.promise.comfort_kept, and copies saved at that moment kept them. Each restart also logged a burst of "catalogs not loaded" warnings. - Now: translations finish loading before any zone starts.
Dashboard (#1590)
- Next 24 hours: a weekday plus a 12-hour time (for example "Sat 12:38 AM") no longer runs into the step text beside it.
- Tables no longer squeeze short columns. The Activity record had shown times as "16:3" / "7" and headers as "Tim" / "e". Times, temperatures and short words now stay on one line; long text still wraps.
Fits Home Assistant better (#1637, #1638, #1647, #1639)
- Each zone's device is listed as a service, and Last Action Time, Last Action Reason and AI Status are diagnostic sensors. Trend is disabled by default on new installs.
- Services are always there from startup, and say clearly when they fail or when a zone isn't loaded.
- Icons follow Home Assistant's icon system, with a different icon for away, vacation and guest.
- A failed update logs its error once, not every 30 minutes until it recovers.
- After a zone is reloaded or deleted, the dashboard and services answer only for zones that are running.
- The README has Troubleshooting, example automations, supported devices (Ecobee tested), removal, how data updates and known limitations.
Gold on Home Assistant's quality scale (self-assessed) (#1637, #1671)
- Home Assistant doesn't grade custom integrations. Our own check of its 54 rules now meets every Bronze, Silver and Gold rule. The README badge shows where it stands, and only two Platinum items are left.
- Behind that: every part of Climate Advisor now has over 95 % test coverage (97.8 % overall, up from 94 %), and the build fails if one slips back under.
Tested more thoroughly (nothing changes in your house)
What is checked now (#1238, #1243, #1254, #1604, #1614, #1641, #1644, #1645, #1728)
- New checks stop background work from freezing Home Assistant the way #1722 did: every job Climate Advisor hands to a background thread is listed with a measured cost, and a real Home Assistant test confirms the learning keeps Home Assistant responsive. The nightly simulation writes a report of how much processor time each job used, now including a household with a week-long forecast.
- The setup wizard and every settings section are tested in real Home Assistant, including bad input followed by a fix.
- CI now fails if any module's test coverage drops below its floor, and keeps 70 modules strictly typed; both lists only grow.
- New real-Home Assistant tests guard: keeping a whole-house fan started from its RF remote through a restart; no leftover "manual override: off" after Off, then heat, then cool; and no fan or AC start in the first minutes after a restart, before the start-up check of the house.
- The simulations press the Cancel Override and Cancel Fan Override buttons the way the dashboard does, and fail a scenario that expects a setback that was never sent.
- The changelog matches the published releases again, and a check keeps it that way.
- The nightly simulation runs in four parallel parts so it no longer runs out of time, a timed-out check is reported as a timeout and diagnosed, and the real Home Assistant tests fail if a scenario steps its clock far more often than it should (the cause of a test slowdown found and fixed in this release). (#1740, #1743, #1745)
- The nightly auto-diagnosis now signs in to Claude with a short-lived token from its GitHub identity instead of a stored one, and says why when it cannot run. (#1625)