Skip to content

boardwright 0.4.0

Choose a tag to compare

@github-actions github-actions released this 15 Nov 16:53
· 8 commits to main since this release
21a7f8e

Added

  • A MOVE entry can place the part's reference and value text:
    {"R10": (25, 25, 270, {"ref": (25.2, 27.4, 0)})} (#25).
  • existing apply checks each part MOVE moves (pads against other nets'
    copper and the board edge, courtyard against courtyards) and writes
    nothing on a clash unless given --force; existing free REF [near PAD]
    lists clear spots for a part (#24).
  • existing update: carry schematic changes to the board, as KiCad's
    Update PCB from Schematic does, from KiCad's own netlist (the last part of
    #3). New parts land beside the board on their nets; references, values
    and pad nets follow the schematic; a footprint swap, a missing footprint
    or a symbol without one stops it with nothing written. Checked by KiCad's
    DRC schematic parity.
  • sch add adds on a sub-sheet used once: SHEET = "file.kicad_sch" in
    the spec (part of #3). Parts take the sheet's hierarchy path; sheet-pin nets
    get hierarchical labels; power symbols are copied from whichever sheet has
    one; a net local to another sheet is refused. References are checked across
    every sheet, not only the root.
  • sch add and sch repoint find a library in KiCad's global
    sym-lib-table too, after the project's: its path variables (Preferences >
    Configure Paths, or the environment) are filled in and tables nested in it
    are followed. KICAD_CONFIG_HOME names KiCad's settings folder; otherwise
    the newest one in the usual places is used.
  • sch add takes a library symbol LIB:NAME as like, so a part can be
    added whose symbol the schematic does not use yet (part of #3). Its pins
    are labelled with the kind of label each net already uses, so add now
    also works on sheets connected by global labels, such as generated ones.

Changed

  • sch add sizes the free area from each part's pins and labels instead of
    a fixed 12.7 mm per part, keeps 20 mm from the sheet edge, and turns each
    power symbol to point away from the part it connects (a +3V3 on a pin that
    faces down used to be drawn over the part).

Fixed

  • Pad-to-pad routes that share a pad no longer stack a via each at it, 0 to
    0.3 mm apart (KiCad's hole_to_hole): a route changes layer on its own
    net's existing via or through-hole pad without adding one (#23).
  • A preview (place, existing apply, existing info) crashed with exit 2
    after the board was written when rsvg-convert was not installed; it now
    stays SVG, as doctor says.
  • Generated boards now link each footprint to its symbol (path,
    sheetname, sheetfile), as KiCad does; kicad-tools wrote no link, so
    renaming a part in the schematic orphaned its placed footprint (#26). The
    example boards are linked. existing update adds the link when it matches
    a footprint by reference, like KiCad's re-link.
  • sch add found a cached symbol only if (symbol "LIB:NAME" fit in the
    first 40 characters of its entry, so a long name such as
    My_Connector_Library:1217861-1_Tab was refused as not cached.
  • The STM32F103 examples (stm32f103_min, stm32f103_4l) take 100 nF on
    VDDA, as ST AN2586 Rev 8 section 2.2 asks; they had 10 nF, written from
    memory (#6). Every example's reference document has now been read.
  • live status names the open board by its full path, and live apply
    prints that path before it edits, so two copies of a board with the
    same file name can be told apart (#17).