Added
A MOVE entry can place the part's reference and value text: {"R10": (25, 25, 270, {"ref": (25.2, 27.4, 0)})} (#25).
existing apply checks each part MOVE moves (pads against other nets'
copper and the board edge, courtyard against courtyards) and writes
nothing on a clash unless given --force; existing free REF [near PAD]
lists clear spots for a part (#24).
existing update: carry schematic changes to the board, as KiCad's
Update PCB from Schematic does, from KiCad's own netlist (the last part of #3). New parts land beside the board on their nets; references, values
and pad nets follow the schematic; a footprint swap, a missing footprint
or a symbol without one stops it with nothing written. Checked by KiCad's
DRC schematic parity.
sch add adds on a sub-sheet used once: SHEET = "file.kicad_sch" in
the spec (part of #3). Parts take the sheet's hierarchy path; sheet-pin nets
get hierarchical labels; power symbols are copied from whichever sheet has
one; a net local to another sheet is refused. References are checked across
every sheet, not only the root.
sch add and sch repoint find a library in KiCad's global sym-lib-table too, after the project's: its path variables (Preferences >
Configure Paths, or the environment) are filled in and tables nested in it
are followed. KICAD_CONFIG_HOME names KiCad's settings folder; otherwise
the newest one in the usual places is used.
sch add takes a library symbol LIB:NAME as like, so a part can be
added whose symbol the schematic does not use yet (part of #3). Its pins
are labelled with the kind of label each net already uses, so add now
also works on sheets connected by global labels, such as generated ones.
Changed
sch add sizes the free area from each part's pins and labels instead of
a fixed 12.7 mm per part, keeps 20 mm from the sheet edge, and turns each
power symbol to point away from the part it connects (a +3V3 on a pin that
faces down used to be drawn over the part).
Fixed
Pad-to-pad routes that share a pad no longer stack a via each at it, 0 to
0.3 mm apart (KiCad's hole_to_hole): a route changes layer on its own
net's existing via or through-hole pad without adding one (#23).
A preview (place, existing apply, existing info) crashed with exit 2
after the board was written when rsvg-convert was not installed; it now
stays SVG, as doctor says.
Generated boards now link each footprint to its symbol (path, sheetname, sheetfile), as KiCad does; kicad-tools wrote no link, so
renaming a part in the schematic orphaned its placed footprint (#26). The
example boards are linked. existing update adds the link when it matches
a footprint by reference, like KiCad's re-link.
sch add found a cached symbol only if (symbol "LIB:NAME" fit in the
first 40 characters of its entry, so a long name such as My_Connector_Library:1217861-1_Tab was refused as not cached.
The STM32F103 examples (stm32f103_min, stm32f103_4l) take 100 nF on
VDDA, as ST AN2586 Rev 8 section 2.2 asks; they had 10 nF, written from
memory (#6). Every example's reference document has now been read.
live status names the open board by its full path, and live apply
prints that path before it edits, so two copies of a board with the
same file name can be told apart (#17).