v1.17.0 — renewals checked properly, clock-change-proof temperature time
What you get
- A renewed timed setting is checked properly. EvoHome Heating Controller renews a room's timed setting at the same temperature with a later end time. The plugin used to count a renewal as taken as soon as the controller's regular broadcast showed the same temperature, which it would have shown anyway, so a renewal lost on the radio was never resent. Now the controller has to report the whole setting back, the temperature, whether it is timed or permanent, and when it ends, and the plugin resends until it does.
- A change made by hand at the same temperature is no longer taken for Indigo's. A change now counts as Indigo's only when the kind of setting and its end time match what Indigo sent as well, so EvoHome Heating Controller leaves it alone.
- New zone state, Temperature Last Reported (seconds). The time of the last temperature as a count of seconds, which the clocks going back on 25 October cannot confuse. EvoHome Heating Controller 1.18.1 uses it.
Install: download RAMSES_ESP.indigoPlugin.zip, unzip it, and double-click RAMSES_ESP.indigoPlugin.