Skip to content

Dive Samples Tab

houle988 edited this page Nov 18, 2026 · 7 revisions

Dive Detail — Samples Tab

The Samples tab (icon: waveform) exposes the raw, time-stamped profile data recorded by your dive computer. It shows the units the dive was imported in, the sync fingerprint that identifies it, and a table of the measurement points captured during the dive.

Showing the Samples tab

The Samples tab is hidden by default. To show it, turn on Samples in Settings → Dive Profile → Dive Detail Tabs, where you can also choose its position among the other tabs (see Dive Detail — Overview Tab). Before BlueDive 2.2 this was the Show Samples tab switch in Settings → Dive Profile; your choice was kept when it moved. The setting is kept on each device and is not synced through iCloud. If you turn it off while the Samples tab is open, the dive returns to the Overview tab.

Sections

The tab presents its information in three stacked sections, in this order:

1. Imported Data Format

A four-cell grid summarizing the units the dive was originally imported in. BlueDive stores each dive exactly as it was imported and never rewrites these values, so this section tells you the source units regardless of the display units you have chosen in preferences.

The grid shows:

  • Distance — the unit used for depths (for example, metres or feet).
  • Temperature — the unit used for temperatures.
  • Pressure — the unit used for tank pressures.
  • Volume — the unit used for tank volumes.

For how these interact with the units you see elsewhere in the app, see Units & Preferences.

2. Fingerprint

The sync fingerprint associated with this dive, displayed as a spaced hexadecimal string that you can select and copy. A copy button sits at the top-right of the section; tapping it copies the fingerprint and briefly shows a checkmark to confirm. When a dive has no fingerprint, this section shows a dash. See Dive Computer Sync & Fingerprints.

3. Raw Data

A horizontally scrollable table of the samples recorded during the dive. The section header shows the total number of points (for example, "Raw Data (240 points)"). Rows alternate shading for readability, and each column has a fixed heading. Columns widen to fit their heading when it is longer than usual (for example in French), so headings never wrap; a long list of events wraps onto several lines within its row.

To scroll the table sideways, swipe horizontally (touch, trackpad, or Magic Mouse), or hold Shift while using a mouse scroll wheel. There is no visible horizontal scroll bar.

The table first shows the first 150 samples. When the dive has more, a Show all N points button below the table shows the rest. Moving to another dive returns to the first 150 rows.

Unlike the rest of the app, some columns show the values as stored rather than in your display units, and only the Temp. and CNS cells carry a unit symbol. The columns are:

  • Time — the elapsed time of the sample, in seconds.
  • Depth — the depth at that moment, in the dive's stored distance unit (the Distance shown under Imported Data Format), not your preferred depth unit.
  • Temp. — the water temperature in your preferred temperature unit, with its symbol, or a dash when none was recorded.
  • Pressure — tank pressure in your preferred pressure unit. When the dive recorded pressure for only one tank, the column is labelled Press.; when it recorded pressures for several tanks, each gets its own column (T1, T2, and so on), with a dash where a given tank has no reading.
  • PPO₂ — the oxygen partial pressure in bar, or a dash when none was recorded. For dives with per-sensor PPO₂ data from a CCR rebreather, individual O₂ cell columns appear alongside the composite value — labelled S1, S2, S3, and so on — each colour-coded by its oxygen partial pressure level.
  • SP — the CCR setpoint in effect at that moment, in bar. This column appears only on dives whose dive computer recorded a setpoint, and shows a dash where no setpoint applies, for example during an open-circuit bailout.
  • CNS — the oxygen toxicity (CNS) percentage at that moment, as reported by the dive computer, or a dash when none was recorded. The dive's overall CNS % is shown on the Gas tab.
  • NDL — the remaining no-decompression limit in minutes, or a dash when none was recorded or no limit applies.
  • Ceiling — the decompression ceiling depth at that moment, in the same stored distance unit as the Depth column, or a dash when the dive computer doesn't report one.
  • Stop — the time still required at the current ceiling, in minutes, or a dash when none is owed.
  • TTS — the time to surface reported by the dive computer, in minutes, or a dash where none was reported. This column appears only on dives that have TTS values.
  • RBT — the remaining bottom time reported by the dive computer's air integration, in minutes, or a dash where none was reported. This column appears only on dives that have RBT values.
  • Gas — the active tank at that moment, shown as a tank label such as T1 or T2, or a dash when unknown or when it doesn't match one of the dive's tanks.
  • Events — any events the dive computer flagged at that point, listed together and separated by commas.

TTS and RBT are shown exactly as your dive computer recorded them, never estimated, rounded up to the next whole minute as dive computers show them (a value recorded with seconds keeps its seconds in the logbook). A few things to know:

  • They come from Bluetooth downloads and from Garmin FIT, Subsurface, UDDF (RBT only) and BlueDive XML files. MacDive XML files carry neither value, but the MacDive migration script can add them from MacDive's raw dive computer data.
  • Dives imported before BlueDive 2.2 have no TTS or RBT until you download them again from the dive computer (for example with a full re-download, see Importing Dives via Bluetooth Sync).
  • A TTS of 0 is not stored: many dive computers report 0 when they don't track TTS. An RBT of 0 is a real reading (no bottom time left).
  • RBT needs air integration with gas time remaining turned on in the dive computer (on Shearwater, GTR). It appears only on the samples where the computer reported it, so it can stop partway through a dive — for example during decompression on a Shearwater.

The events that can appear in the Events column are:

  • Ascent — an ascent-rate warning.
  • Violation — a decompression violation.
  • Deco — a decompression stop was required.
  • Gas Chg — a gas change.
  • Bookmark — a marker you or the computer placed.
  • Safety — a safety stop (shown as Safety (M) when mandatory).
  • Ceiling — a ceiling violation.
  • PPO₂ — an oxygen partial-pressure warning.
  • Deep Stop — a deep stop.

No samples?

Manually-entered dives have no continuous profile, so this tab shows a placeholder instead of the sections above:

No samples available Import a dive from your dive computer to see detailed data.

Related pages

Clone this wiki locally