Remove Ghidra references from official updater documentation
Document official Windows updater analysis and Go updater AZ01 support
Reverse engineered the official Windows updater EXEs (4.3.4 and 5.0.0)
with Ghidra: both firmware generations ship the exact same
FirmwareUpdater.exe binary, which auto-detects the container format
and dispatches to a dedicated "AZ01 programmer" component for the new
format while reusing the same fastboot-derived USB protocol
(getvar/download/flash/reboot) for both.
- Firmware-image-structure.md: replace the Update Mechanism section
with a detailed breakdown of FirmwareUpdater.exe's capabilities
(OEM commands, BCrypt/RSA usage, fastboot command set) and the
actual multi-step update flow.
- Firmware-formats-comparison.md: add a new Official Updater Tool
Analysis section plus a Go Updater Tool Status note documenting
that go/pkg/updater now supports both the legacy FIT format and
the new AZ01/SC6000 format in a single build.
Rename ExtraValues to USBDeviceIDs in header
The 'extra values' field in the AZ01/SC6000 header contains USB VID/PID
pairs (VID=0x15E4 Numark), not arbitrary build numbers. Renamed the
field to USBDeviceIDs to accurately reflect its purpose.
Correct AZ01/SC6000 partition chain structure
The per-partition marker is 'PART' (4 bytes) plus a little-endian
uint32 giving the entry's own metadata length, not one of three
distinct 5-byte markers (PARTP/PARTX/PARTL) indicating a partition's
position in a table. The apparent letter suffix was a coincidence of
the length value (80/88/76 bytes) matching a printable ASCII code.
There is also no separate, fixed-size partition table: the image is
a simple chain of name+metadata+data blocks (splash, recoverysplash,
rootfs) terminated by an EOF sentinel, not a fixed 4096-byte table
with entries for boot/system/cache/recovery/misc/firmware/data/persist
(those partition names exist only in the on-device eMMC/U-Boot
layout, not inside the update image file).
The rootfs .xz stream also turned out to have a complete, valid
footer all along - extraction just needs to stop at the partition's
exact declared data size instead of reading to the end of the file.
Verified against 8 real firmware images (PRIME 4, PRIME 2, PRIME GO,
SC5000, SC5000M, SC6000, SC6000M, Mixstream Pro) with full SHA-1 hash
verification via a new Go implementation (go/pkg/az01).
Updated Firmware image structure (markdown)
Updated Firmware image structure (markdown)
Add scope note to AZ01 document and update references to point to firmware formats comparison
Update device list with in-image product codes and add format notes to firmware structure
Updated Firmware image structure (markdown)
Updated Firmware image structure (markdown)
Updated Firmware image structure (markdown)
Updated Firmware image structure (markdown)
Clarify --single-stream is advanced option
Document incomplete XZ stream and --single-stream extraction
Document XZ extraction issue and binwalk workaround
Update wiki: fix JC16 references, remove tool section, add device list
Add mermaid diagrams to firmware and SSH persistence guides
Updated Firmware image structure (markdown)
Add Denon PRIME 4 firmware image structure documentation