v0.6.0

Latest

Choose a tag to compare

@samuelduchesne samuelduchesne released this 10 Nov 20:41

This release makes the building's orientation a sweepable control, adopts the idfkit visual identity, and corrects three reading errors: the TM59 night window under daylight saving, the economizer's flow limit on stacked storeys, and two unit-lettering faults. Every v0.5.0 permalink still opens to the same building.

Features

  • North axis can be studied, surveyed and pulled round the whole turn (#113). A study draws a closed curve on the card, 8 bearings then 16, with its extremes lettered as compass bearings. Either axis of an E-02 survey can be North axis, and the ground has no seam at north; a narrowed extent may run through north, so 300° to 60° is cut the short way round. The pull ranks it like any other control, turning the building 18° clockwise.

  • The study curve stands under its slider and can be probed (#105). The plot spans the full width of the face above it, so each position on the curve sits under the same position on the slider. Hovering letters the reading at that position, interpolated between solved samples and marked ≈; clicking sets the control there, snapped to its step.

  • The link records whether the model console is open (#109). An open console adds desk=open to the address and to Share. A closed console adds nothing, so existing links are unchanged. Kept schemes do not store it.

  • The sheet wears the idfkit identity at identity-2026.5 (#102), with the Shoebox lockup at the head of the title block. Colours, typefaces, favicons and the social image come from the standard; the drafting sheet's own colour names survive as aliases.

Fixes

  • TM59 criterion b reads the right nine hours under daylight saving (#111). EnergyPlus stamps hourly output in standard time, so with daylight saving observed the window read was 00:00 to 09:00 local instead of 23:00 to 08:00. Every TM59 reading now places each stamp on the local clock. Runs without daylight saving read exactly as before.

  • TM59 criterion a counts an hour whose ∆T is exactly 0.5 K (#111). Floating-point representation had dropped such hours for 127 of the 402 thresholds between running means of 10 °C and 30 °C.

  • The economizer's cooling flow limit covers every storey (#101). It was sized on one storey's volume, so above a zone multiplier of 1 the system ran at the limit without warning: 2,595 of 2,600 occupied hours in one reported scheme. Single-storey desks write the same IDF as before.

  • The default desk runs with no warnings (#112). Two Other Equipment series were still requested after the objects that produce them were removed.

  • Landmark tooltips, slider descriptions and the airtightness line follow the unit system (#108). The arithmetic line had mixed IP area and volume with an SI density, giving 35.3 times the coefficient it explains.

Changes

  • Links are now v2 (#113). A v1 link carrying northAxis=360 opens at 0°, the same building; a v2 link carrying 360 is refused.
  • "Cost" is now "Utility cost" in studies, surveys and the kept-scheme column (#104). The link token cost is unchanged.
  • The duration curve's cursor follows a hovering mouse (#106); a press still sets it on a touch screen.
  • MIT licence added, and the README corrected against the code (#110).