Added
TCP Simulator (Modbus TCP server). Turn the workbench into a Modbus TCP
server so external masters (SCADA/PLCs/test tools) can poll and write the app
as virtual devices. Serves all four banks — Coils (0x01), Discrete Inputs
(0x02), Holding (0x03/0x06/0x10), and Input (0x04) — across multiple Unit
IDs on one port. Start/Stop with an Expose toggle (LAN 0.0.0.0 / Local only 127.0.0.1), a configurable port, and a status dashboard (Exposed / Accessible
At / Connected Clients / Tick Interval) plus a footer strip.
Register value sources: Hold (fixed, live-editable), Device presets
(temperature, humidity, pressure, flow, vibration, analog, discrete, counter), Generators (sine, ramp, decrement, step, random, toggle), and Route.
Data types u16/i16/u32/i32/f32/u64/i64/f64 with byte order
(ABCD/BADC/CDAB/DCBA) and per-register update intervals; live values stream to
the UI.
Route from slave (Modbus gateway). Mirror a live value read from a
connected real slave (serial RTU or TCP) with scale/offset transforms and
an optional source byte order, and an ok/stale/missing source-status badge.
The simulator now opens the source connection itself on Start (reusing an
already-open shared connection), so routing no longer requires the Slaves page
to be actively connected.
Automation rules — trigger (interval / register condition / on client
write) → one or more actions (set/inc/dec/toggle/copy/randomize) with an
optional per-action delay and multi-word/typed targets. Rules run once
per tick in sort order after generators/routes update.
Activity tab — server uptime, a connected-clients list (address + duration),
and a rolling event log (started/stopped, client connect/disconnect).
Profile export / import — snapshot a workspace's entire simulator setup
(config + devices + registers + rules) to a file and restore it later
(workspace-specific; import requires the server stopped).
Virtual Devices — a top-level tab (beside Workspaces) for reusable,
app-global device blueprints shared across every workspace's simulator:
A built-in catalog plus fully editable custom devices; built-ins are
immutable and can be Cloned & edited or exported only.
A device builder with name/key/category/description, a searchable
icon picker, and a register map whose per-register parameters switch
between a Form view and a raw JSON view.
Add Device wizard in the simulator instantiates a device at a chosen
Unit ID + base address, with a register-map preview and collision check.
Save as virtual device — promote a configured live simulator device into
the catalog (pre-filled in the builder, key clash-guarded).
Expose a real slave as a routed device — a "Workspace" category in Add
Device turns any of the workspace's slaves into a one-click routed gateway.
Export / import a device as a self-contained .json for community
sharing, via native file dialogs.
Changed
TCP Simulator: a tabbed workspace (Registers, Devices, Rules, Live Values, Activity) with a status dashboard, register search/filter/columns/pagination,
the Add-Device wizard, and a right-hand register inspector (live sparkline,
Duplicate, persisted Unit/Display Format). Header buttons for Profile
export/import. Sidebar collapse state now persists across restarts.
Fixed
Expose a real slave as a device now works for slaves that have coil or
discrete-input registers. Those bit-bank registers are mapped to the correct u16 (0/1) route type instead of bool, which the register validator
rejected — previously the whole "add slave as device" action failed for any
slave with a coil/discrete register.
Editing a running simulator register to a narrower data type (e.g. f64
→ u16) no longer leaves stale "ghost" words being served at the vacated
addresses; the previous span is cleared before the new value is seeded.
Duplicating a register now searches for a free slot span-aware: it accounts
for every existing register's full word span (not just its start) and places
the copy's whole span in a free, in-range gap, so duplicating a multi-word
register no longer lands inside another register's tail (and reports clearly if
the map is full).
Manually adding or editing a multi-word register (and importing a Profile)
now rejects configurations whose word span would overlap another register,
closing a silent live-bank corruption path that the address-only uniqueness
check missed.
A multi-word register can no longer be placed so its span runs past address
65535 — an f64 near the top of the map used to wrap its tail words back to
address 0. Such registers are now rejected on add, edit, and Profile import.
The Help button now opens the section for the page you're on — TCP
Simulator, Virtual Devices, Slaves, Analyzer, etc. — instead of always the
overview.
Deleting a simulator rule now asks for confirmation (parity with register
and device deletes).
Custom dropdown menus (the Registers Columns chooser and the Analyzer tile
menus) now close on Escape and on an outside click.
The register-map Add Device wizard trimmed to two steps (removed the Review
step); Prev/Next pagination controls use icons.