Repository navigation
loadbearer v1.7.0
What the run was allowed to do. A laptop on battery, or in a
power-saving mode, comes in slow for reasons that have nothing to do with its
hardware — and until now the only hint was a note when it was on battery.
loadbearer now records the power settings in force and names whatever held a
run back. No measurement changes: 1.6.x scores and result files are directly
comparable, and nothing here touches a grade.
- A POWER block in a scored report and the results screen, and a Power
section ininfo: mains or battery, and the plan, mode or profile in force.
Its note names what held the run back — battery power, energy saver, Best
power efficiency, a maximum processor state below 100%, boost or turbo off,
a low-power platform profile. The battery block's old "on battery" note
gives way to it. - Windows: both columns. Every power setting on Windows has a plugged-in
and an on-battery value, and both are shown: the Windows 11 power mode (Best
power efficiency / Balanced / Best performance) beside the plan's processor
limits and boost mode, plus energy saver. The power mode is applied on top of
the plan without changing its figures, so they're labelled as the plan's.
No elevation needed. - Linux: what's in force now, since Linux has no plugged-in / on-battery
split: the ACPI platform profile (which power-profiles-daemon and tuned-ppd
set), the CPU governor and energy-performance preference, and whether turbo
is on. Apowersavegovernor alongside a preference is the normal
intel_pstate / amd-pstate setup and isn't counted against the run. - In the result file as
machine.power, for a fleet collector:source,
the plan's name andplan_guid(the name is in the OS's language), the two
Windows columns, the Linux readings, andheld_back— the settings that
would hold a benchmark back, so a collector needn't repeat the rules. New
optional fields underloadbearer.result/1, so nothing reading 1.6 files
breaks. The wording inheld_backis descriptive and not covered by
VERSIONING.md; key on whether it's empty.
loadbearer-fleet 0.8.0 reads
it.
Vendor tools that apply their own limits — Dell Optimizer's thermal modes,
Lenovo's Intelligent Cooling — don't appear in either OS's settings, so a
machine can still be held back without the block saying so.
Full Changelog: v1.6.0...v1.7.0