For everyone updating from 4.3.18: the Create Chart log now warns about poor contrast between a patch and the spacer beside it only where that is really printed, names those strips, and is translated, like the rest of the layout engine's lines. With the beta option that lets i1Profiler measure a printed ChromIQ sheet, a measurement that i1Profiler laid out on another grid than the note names is now refused instead of being filed onto the wrong patches, and the i1Pro 2 file has now been checked in i1Profiler 3.8.6, the last version that supports that instrument, which the note now names. Your charts, presets, measurements and profiles do not change.

Fixed

  • The log note "low patch/spacer contrast" only appears where it is true. Since 3.13 it appeared on most charts made with the ChromIQ layout engine, also with Spacers set to "Coloured" (the default) or "None", where it meant nothing: a coloured spacer is always chosen to stand out from both patches beside it, and with no spacers there is nothing between the patches at all (there it even named the strips where neighbouring patches differ the most). The note now only appears where a black or white spacer is really printed right beside a patch that looks almost the same: with Spacers set to "Black & white", where a very dark patch sits right next to a very light one, so the spacer between them looks almost like one of the two, and also where a strip starts or ends on a very dark patch next to the black spacer that "Edge spacers" prints at the end of a strip. It names the strips by their strip names, the letters ChromIQ prints above them when strip letters are on, explains what that means in plain words, says what to do if such a strip does not read cleanly, and is translated. A spacer you recoloured by hand is checked by its own colour, with Spacers set to "Coloured" or "Black & white" (with "None" no spacer is drawn, so there is nothing to check): if you chose black or white for it and it looks almost like a patch beside it, its strip is named; a colour other than black or white is not checked. Charts for the SpectroScan and the CR30, honeycomb charts included, never get the note: those instruments are put on each patch at its position and do not look for the edge between a patch and a spacer. Your charts themselves do not change.
  • Preferences > Chart Layout: the warnings about patches that are too small and about strip letters wider than a strip are translated. The first one also says what really makes the patches larger now, for the way your chart is laid out. With "Prioritise chart area, then fit patches to it" it names the setting for the side that is too small, from the ones the calculation method shows: when the patches are too narrow, fewer "Strips (columns)" or a larger "Minimum patch width"; when they are too short, fewer "Patches per strip (rows)" or a larger "Minimum patch height"; and both when both sides are. On a honeycomb, whose height follows its width, it names the strips or the minimum width. With a patch size you typed in, it says to type a larger "Patch size", because "Patch scale" does not change a typed size. Otherwise it says to choose a larger "Patch scale". It used to say "reduce the scale", which makes the patches smaller still.
  • "Drawing the pages. This part runs in one go and cannot be stopped…" in the log is translated. It was shown in English in every language.
  • The layout engine's other lines in the Create Chart log are translated, and the summary calls the seed "Seed", as the panel does. "441 patches (21×21), 1 page, random start 1007764308" now reads "441 patches (21×21), 1 page, Seed: 1007764308" in your language, and so do the fill-up line, "building chart from the targen .ti1…" and the error line.
  • A measurement of the turned i1Profiler chart is refused when i1Profiler laid that chart out on another grid (beta option, off unless you switch it on). If i1Profiler made a different grid from the one the chart's note names, for example 25 columns instead of 24, its rows did not line up with the strips on your sheet and the readings belong to other patches, but the import still said the file fitted, because i1Profiler writes the colours of its test-chart file into every measurement. An .mxf file records i1Profiler's grid and where it put each patch, so ChromIQ now compares them with the grid the note names. When they differ, nothing is filed, and the message says what happened and how to measure again. When i1Profiler kept the note's columns but cut the chart over several pages, the message says exactly that: i1Profiler then numbered its rows page by page, so the note's list of which row is which strip did not match what it showed you, and nothing in the file shows whether every row was still read on the right strip. Such a file is refused too, as step 5 of the note says. A CGATS text export does not record the grid and is checked as before. Nor does a measurement that an earlier ChromIQ already brought in and converted to a .ti3 file, so that one cannot be checked; its .mxf file can, when you import it again.
  • The i1Pro 2 file is now checked in i1Profiler, and the note and the option's help in Preferences say which i1Profiler you need for it (beta option). Cell by cell in i1Profiler 3.8.6, the last version that supports the i1Pro 2, it lays out exactly like the printed sheet on A4, Letter, A4 landscape, 4 x 6 inch and 5 x 7 inch paper, and on A4 with 7 mm patches. Nobody has yet read such a sheet with a real instrument. You need i1Profiler 3.8.6 or older for the i1Pro 2, because X-Rite removed the i1Pro 2 from i1Profiler in version 3.8.7. i1Profiler 3.8.7 and newer open the i1Pro 2 file as a file for the i1Pro 3 family, without a warning, and lay it out on another grid, so its rows would not match your sheet. The note also says to leave i1Profiler's "Use legacy charts" setting off, for either instrument: with it on, i1Profiler 3.8.6 draws the i1Pro 2's older chart, with divider bars between the patches and a different grid, which does not match the sheet. The files ChromIQ writes ask for it off.
  • The i1Profiler workflow file writer places patches on several pages the way i1Profiler does. Its option to write each patch's place filled one page after the other, while i1Profiler fills one grid column by column and then shares its rows out over the pages, so on a chart of more than one page most places were wrong (26 of 702 right on a three-page file). ChromIQ does not use that option for any file it writes, so no chart or file of yours was affected.

Installation (Linux, beta): Download the tarball for your architecture (x86_64 for most desktops/laptops, aarch64 for ARM systems like Raspberry Pi 4/5). Extract with tar xzf ChromIQ-Linux-*.tar.gz, then run ./ChromIQ/ChromIQ. Requires ArgyllCMS — install via your package manager (sudo apt install argyll) or from argyllcms.com/downloadlinux.html.


☕ ChromIQ is free and always will be — if it saves you time or ink, a coffee is a kind way to say thanks. Completely optional, and the app stays fully featured either way.

Support ChromIQ on Ko-fi