ChromIQ v4.3.35

Choose a tag to compare

@github-actions github-actions released this 14 Nov 09:29
· 304 commits to master since this release

For everyone updating from 4.3.34: the lights beta option now gives the X-Rite i1Pro 3 and i1Pro 3 Plus the same two choices as the i1Pro 2, and a new beta option uses the ruler of an i1Pro 2 or i1Pro 3 to check each strip you read. Both are off by default, and neither has been tried by the project on real hardware, so if you own one of these instruments and would like to help test, you are very welcome. On the Create Chart tab a small round button now folds away the two boxes under the chart preview, and the page buttons of a chart with several pages sit together in the middle. Among the fixes: a project name that ChromIQ corrected, or one given in the naming window, could build the new project with the previous project's paper and settings. With every beta option off, your charts, measurements and profiles are made as in 4.3.34, except where one of the fixes below changes the result; on screen, the fold button and the page buttons look different.

New

  • Result signals for the lights of an X-Rite i1Pro 3 too (beta). The two choices of “X-Rite i1Pro 2 and i1Pro 3: show the instrument's state with its lights (beta)” in Preferences › Beta now apply to the i1Pro 3 and i1Pro 3 Plus as well, and are now called “What the lights show” and “During a reading”.
    • What the lights show: with “Ready light and result signals (green / red)” an i1Pro 3 blinks green twice after a strip or patch that ChromIQ accepted and red twice when ChromIQ wants you to look at the screen, just like an i1Pro 2. The first choice is now called “Ready light; the instrument's own green / red (i1Pro 3)”: on an i1Pro 2 it shows the ready light only, as before; on an i1Pro 3 it shows what 4.3.34 showed, where green and red only say whether the instrument itself took a reading.
    • During a reading: “Left on during a reading” now also sends an i1Pro 3 no off command before a reading started with the instrument's button, as i1Profiler does; before a calibration, and before a reading started from the keyboard, the off is still sent.
    • If you switched this on in 4.3.34: your i1Pro 3 now uses “Ready light and result signals”, the default then (the choice was labelled for the i1Pro 2 only in 4.3.34): green and red now follow ChromIQ's verdict on the strip. Choose “Ready light; the instrument's own green / red (i1Pro 3)” to keep what your i1Pro 3 showed before. With that choice and “Off during a reading”, an i1Pro 2 and an i1Pro 3 receive exactly what 4.3.34 sent.
    • The patterns are the ones X-Rite's i1Profiler sends, recorded on users' own instruments. The measurement log names the i1Pro 3's firmware. Nobody on the project owns an i1Pro 3, so this has not been tried on a real instrument yet.
  • A ruler check for the X-Rite i1Pro 2 and i1Pro 3 (beta). A new option in Preferences › Beta, “X-Rite i1Pro 2 and i1Pro 3: check each strip with the ruler (beta)”, off by default. When you scan a strip, the instrument slides along its plastic ruler and counts the stripes on it, so it can tell how far it moved, in which direction and how fast; X-Rite's i1Profiler uses this on every strip. With the option on, the ChromIQ chart-reading engine uses the ruler to check each strip:
    • After every strip the Measure log shows how far, which way and how fast the instrument moved. When ChromIQ has accepted a strip but the ruler says the instrument clearly did not pass over all of its patches, ChromIQ asks whether you would like to read that strip again.
    • It only checks, and never changes a measurement. The colour values, and which reading belongs to which patch, are worked out exactly as without the option. When the ruler data is missing or incomplete, the strip is read the usual way and the log says so.
    • What the instrument receives: an i1Pro 3 already reports its ruler on every strip, so nothing new is sent to it. An i1Pro 2 is asked for its ruler while a strip is read, the way i1Profiler asks for it: two extra switches in the measure command, and its ruler channel is read during the strip. Nothing is ever written into the instrument's memory, and if anything about the ruler looks unusual, ChromIQ stops using it for the rest of the measurement and says so in the log. On a Mac, if an i1Pro 2's ruler signal does not end by itself, ChromIQ ends it on the computer's side when the instrument is let go.
    • A diagnostics file: every measurement with the option on writes a small file into the run's “reports” folder, named “ruler_diagnostics_” with the date and time; the Measure log names it. It holds how the instrument moved along the ruler, where the patches were found, the chart's layout, and a coarse brightness trace in three colour bands, relative to the paper, from which the rough colour of each patch can be seen. It holds no serial number, no calibration data, no file paths and no names.
    • Nobody on the project owns an i1Pro 2 or an i1Pro 3, so the option has not been tried on a real instrument yet. If you have one, you are very welcome to test it, and sending us the diagnostics file in the ChromIQ forum thread or on GitHub helps.
  • Fold away the two boxes under the chart preview. On the Create Chart tab, a small round button in the bottom right corner of the chart preview hides “Measured from Preview” and “Chart layout information” together, and the preview takes their room; a second click shows them again. While they are hidden, a small badge beside the button repeats what they say: a green tick for “Margins: OK”, the number of warnings in red, or the number of notices in grey, with the words in its tooltip; a click on the badge shows the boxes again. ChromIQ remembers whether the boxes are shown or hidden, the same in Guided and Manual mode.

Changed

  • The page buttons sit together in the middle. For a chart with several pages, the buttons for the previous and the next page and the page number now stand together in the middle under the preview on the Create Chart, Print Chart and Measure tabs, and they no longer move while you go through the pages. In a very narrow window they show only their arrows, with their words in the tooltip.

Fixed

  • A new project could be built with the previous project's paper and settings. When you typed a new project name with a file ending, such as “Name.icc”, and ChromIQ took the ending off, or when you gave the name in the window that asks for one, ChromIQ treated the name as if it had set it itself, loaded the settings of the project that was open, and built the new project from them, for example on A4 although you had chosen Letter. A name you give is now always treated as typed, and the new project is built with what you chose.
  • Picking the saved preset that is already shown loads it again. In Manual mode, choosing the saved preset that is already selected in the presets list did nothing, even when you had changed its margins, paper or other settings since. It now loads the preset again when the screen differs from it. Picked again, it only loads: it does not rebuild the chart, even for a preset saved to build the chart at once, and the log says so. A first pick of a preset works as before.
  • Choosing “none” in the presets list keeps your instrument. It used to put the instrument back to the saved default or the i1Pro, while the layout panel kept the one you had chosen. The instrument now stays as you chose it everywhere; only the preset is taken away.
  • The layout preset bar in Manual mode no longer counts the layout as changed right after “Reset to preset”. For the i1Pro, the i1Pro 3, the ColorMunki, the SpectroScan and the CR30, the same layout was written in two slightly different ways, so “Reset to preset” and the button beside it stayed available after a reset as if you had changed something.
  • The Measure tab no longer takes keys when no reading is running. Around the start and the end of a measurement there were moments when ChromIQ caught every key pressed in the app for the instrument reader, although no reader was running to receive it. Keys now go to the reader only while it is really running; while you measure, nothing changes.
  • i1iO custom paper sizes (beta). Choosing another paper and going back to the custom size no longer turns a size while you are still typing it. Switching from the i1iO to another instrument turns a size typed lying down, and its note comes back with it. When you press Generate, the boxes first show the size that is built, with its note.
  • An empty chart preview no longer shows the previous chart's warning. When ChromIQ refused a chart, for example an i1iO sheet too large for the table's arm, the preview went empty but “Measured from Preview” still showed the previous chart's “1 warning”.

For developers

  • A counter in ArgyllCMS's shared USB code is now updated atomically in the copy the ChromIQ chart-reading engine is built from, because the ruler check reads the instrument from a further thread. This code is used for every USB instrument the engine drives; nothing sent to any instrument changes.

Installation (Linux, beta): Download the tarball for your architecture (x86_64 for most desktops/laptops, aarch64 for ARM systems like Raspberry Pi 4/5). Extract with tar xzf ChromIQ-Linux-*.tar.gz, then run ./ChromIQ/ChromIQ. Requires ArgyllCMS — install via your package manager (sudo apt install argyll) or from argyllcms.com/downloadlinux.html.