ChromIQ v4.3.37
For everyone updating from 4.3.36: fixes for measuring. With the lights beta option on, an X-Rite i1Pro 2 now gets its lights in the same order as X-Rite's own program, i1Profiler, which a tester's log shows should stop the readings that ended with “The instrument lost communication with the computer”; this has not yet been confirmed on a real i1Pro 2. And continuing a measurement with “High resolution spectral mode (-H)” set differently from when it was started can no longer lose the strips you read: ChromIQ now asks before anything is measured. A strip that the instrument reader saved back to front is now also found when the print is far from the chart's design colours, and with the ruler check beta an i1Pro 3 asks about such a strip. With every beta option off, ChromIQ measures exactly as 4.3.36, apart from two new questions that are not beta: one before continuing a measurement at another spectral resolution, and one about a strip that matches the chart far better turned round. Your charts, measurements and profiles do not change.
New
- The ruler check asks about a strip saved the other way round (beta, i1Pro 3). When the ruler says the instrument moved the same way as on the other strips, but the readings were saved as if the strip had been read the other way round, ChromIQ asks whether to read the strip again or keep it. Which way is “the same way” is learned from most of the strips you have read, not from the first one. ChromIQ never changes a reading by itself.
Changed
- The i1Pro 2's lights follow i1Profiler's order (beta). A tester sent us the log of several sessions with an i1Pro 2. It shows that a reading lost its first part about two times in three whenever ChromIQ had changed the instrument's light a few hundredths of a second before it measured, whichever light it was, and never when no light had changed. That includes the ready light that 4.3.36 still used, so 4.3.36 did not cure it. X-Rite's i1Profiler, recorded on the same instrument, never changes the light between your button press and the reading: it measures with whatever light is showing, and changes the light only after a reading. ChromIQ now does the same on an i1Pro 2:
- no light command while you read: from the button press to the end of the reading, nothing is sent to the lights;
- about two seconds of quiet after every light change before the instrument measures. If you press the button sooner, the reading starts a moment later, and the Measure log says so once. So after pressing, keep the instrument still on the white paper before the strip until it beeps, which can be up to about two seconds later than usual, and start sliding at the beep. If you stop a measurement during this wait, the lights are switched off at once;
- the lights you see: white when ChromIQ connects, off while it calibrates, then a softly pulsing white; with “Ready light and result signals” also green twice after a reading ChromIQ accepted and red twice when it asks you to look at the screen. ChromIQ no longer sends a pulsing light of its own after Retry or when no verdict came, because i1Profiler never does;
- “During a reading” makes no difference on an i1Pro 2 any more: the light stays as it is during a reading with either choice. Your choice is kept and still applies to the i1Pro 3;
- only light patterns recorded from i1Profiler are sent, nothing new. This has not yet been confirmed on a real i1Pro 2: a tester's page read without a single “lost communication” window is what will confirm it. If you see that window with the option on, please switch the option off and tell us.
- The i1Pro 3 is not affected. Its lights work exactly as in 4.3.36. They have not been confirmed on a real i1Pro 3 either: if “The instrument lost communication with the computer” appears with the option on, please switch it off and tell us.
- The ruler check stays paused for the i1Pro 2 (beta), as in 4.3.36, so that only one thing changes at a time.
Fixed
- Continuing a measurement with “High resolution spectral mode (-H)” set differently no longer loses the strips you read. A tester continued a measurement (“Refine / resume”) that had been taken without high resolution, with it switched on. All readings in one measurement file must have the same spectral resolution, but the instrument reader only checks that when it saves, after the strips have been read. So it stopped at the end, ChromIQ took that for a lost connection and tried again with ArgyllCMS's own chartread, which stopped the same way, and the strips just read were lost. Now ChromIQ compares the two before anything is measured and, when they differ, asks: one button continues the measurement at the resolution it was started with, for this measurement only (your setting stays as it is), and Cancel starts nothing. It works in both directions. A measurement taken in high resolution cannot be continued at all with an instrument that has no high-resolution mode, and ChromIQ now says so before anything is measured instead of starting. Should the reader ever stop for this reason, ChromIQ now says so and no longer calls it a lost connection or tries again with chartread.
- A strip saved back to front is now found even when the print is far from the chart's design colours. A tester's i1Pro 3 measurement of a chart in plain order had one strip saved back to front by the instrument reader's strip recognition: every patch of it had the colour of another patch. ChromIQ's own check for this asked the strip to fit its design colours well once turned round, and a real print rarely does, so it said nothing. It now also compares the strip as saved with the strip turned round, and asks you to read it again when turned round fits far better. This also covers a strip scanned from the last patch to the first with bidirectional recognition switched off (“Bidirectional disabled (-B)”), which the reader then saves as it was read, without a warning. On the tester's measurement it finds that one strip and none of the 15 others.
- The ruler diagnostics file now also says why a strip could not be read (beta), in the reader's own words, such as “Not enough patches”: those strips are the most useful ones for improving the ruler check.
- The ruler diagnostics file groups ChromIQ's own charts correctly (beta). On a chart whose strips are numbered and whose patches are lettered, such as “9I”, every patch was taken for a strip of its own, so the file held no strip sizes and the question about a strip not read all the way could never be asked. The file now also records which build of the chart-reading engine made it, and the measurement condition you chose (M0, M1, M2 or M3), or none when you measured without “Spectral filter type (-F)”.
- The ruler check's help no longer says that every measurement writes a diagnostics file: with the paused i1Pro 2 none is written.
Installation (Linux, beta): Download the tarball for your architecture (x86_64 for most desktops/laptops, aarch64 for ARM systems like Raspberry Pi 4/5). Extract with tar xzf ChromIQ-Linux-*.tar.gz, then run ./ChromIQ/ChromIQ. Requires ArgyllCMS — install via your package manager (sudo apt install argyll) or from argyllcms.com/downloadlinux.html.