Skip to content

ChromIQ v4.3.42

Choose a tag to compare

@github-actions github-actions released this 16 Nov 15:09
· 51 commits to master since this release

For everyone updating from 4.3.41: a new beta option for the X-Rite i1Pro 2, which keeps a strip that ArgyllCMS refused only because of the white paper margin; with the i1iO beta option, i1iO charts of several pages can now be measured in i1Profiler one sheet at a time and brought back; and small fixes to the ruler check, the M0, M1 and M2 option, the chart's printed text and the patch set editor. With the beta options off, which is the default, ChromIQ measures, builds and checks exactly as before, and your charts, measurements and profiles do not change.

New

  • Beta: “X-Rite i1Pro 2: keep a strip refused only because of the paper margin” (Preferences > Beta). When you read a strip by hand, ArgyllCMS sometimes refuses one that was read perfectly well: the white paper margin at one end was long enough to count as a patch of its own (“Too many patches”), or the reading began on the first patch with no white paper before it (often “Not enough patches”). With this option on, ChromIQ takes a second look at exactly those strips. It keeps one only when the colours of the whole strip clearly match the strip it should be (at least twice as well as any other strip, a shifted position or the other direction), each half on its own is in place, what is left out at the ends is the paper, and the ruler shows that the instrument moved forwards over each kept patch about one patch length. A kept strip then goes through every check an ordinary strip goes through, its values are worked out exactly as ArgyllCMS works out any patch, and the Measure log says so in one line. A strip ArgyllCMS accepts today never changes. It needs the ruler check (beta) and works only with an i1Pro 2 that reports its ruler.
  • The ruler diagnostics file opens with a summary of the margin tolerance's decisions: how many strips it kept and refused, the refusals grouped by reason, and for every kept strip the numbers the rule used (how the ruler travel was accounted for, how much better the strip fitted than the best alternative). The file stays compatible.
  • i1iO charts of several pages, measured in i1Profiler one sheet at a time (beta, with “X-Rite i1iO support” on). Until now only a one-page i1iO chart could be brought back from i1Profiler's “Measure Chart”. Now the Start window of a chart of several pages lists every sheet with its columns, rows and corner patches; you measure each sheet on the table with “Measure Chart”, save each as a .cmxf file and import them on the Measure tab, one at a time, in any order, or several at once. ChromIQ works out from the grid and the colours which page each file is, puts every reading on its own patch, refuses a file of another chart or a sheet that lay turned round (and says which page and how to lay it), and asks you when two pages look too much alike to tell. You can close ChromIQ in between: the pages already imported stay in the run. The run's measurement is written only when every page is in, and until then Build Profile says which pages are still missing and builds nothing, also when it is still showing a measurement from another project you worked on before.

Changed

  • Ruler check (beta): after a turn, the next strips are compared at once. When the ruler sees a strip the other way round and the strip's own colours confirm the order it was saved in, the check now starts again from that strip's way round. In 4.3.40 and 4.3.41 it waited until enough strips agreed: on a tester's session, four strips in a row after each quick turn back were not compared at all. Replayed on that session's ruler records, with colours that confirm the order as his did where they were looked at, none is left out now. Right after such a turn a strip is also still held against the old way round, so a strip the check would have asked about before is still asked about. One strip turned on its own now gets a second calm note in the Measure log, on the strip after it. On charts whose strips look alike in both directions nothing changes.
  • Ruler check (beta): its help says that turning the sheet or the ruler round is fine, and what the check does after a turn.
  • Beta “M0, M1 and M2”: the help says what has been compared. ArgyllCMS's M0, M1 and M2 values for the i1Pro 3 have now been compared with X-Rite i1Profiler's on one i1Pro 3 and one paper, and they agreed within 0.15 to 0.19 ΔE00 on average. That is one instrument and one paper; other instruments and papers have not been compared yet.
  • Build Profile, “Build from”: the help names the measurement that does not record its condition, which is offered only “As measured (condition not recorded)”.
  • Patch set editor: the line that says which chart is loaded is readable again. At the window's normal size it was cut to nothing, and it named an i1iSis chart “-ii1”, the i1Pro's code. It now has a line of its own and names the instrument a loaded chart was laid out for (for example the i1iSis).
  • Patch set editor: “Ensure unique colours” and “Pure white & black” no longer contradict each other. The help and the tooltip now say that the copies of pure white and black are the one exception: they stay identical on purpose, so their readings can be averaged.
  • Measure tab, “Spectral filter type (-F)”: each entry says what it is, with the measurement condition first: “M0: no filter (lamp as it is)”, “M1: D50 daylight (with UV)”, “D65 daylight filter”, “M2: UV cut (no UV)”, “M3: polarising filter”, in your language. What ChromIQ sends to ArgyllCMS, the entry chosen when you switch the row on (M1) and your saved settings and presets are unchanged. The row's help now also says which instruments accept which entry: in ArgyllCMS 3.5.0 the i1Pro 3 accepts M0, M1 and M2 (M3 only with a polariser), the Spectrolino M0, the D65 filter, M2 and M3, and instruments without such modes or filters, such as the i1Pro 2 and the ColorMunki, none of them: the measurement then does not start.

Fixed

  • A ChromIQ layout engine chart whose patch order is not randomised no longer prints a seed. The seed only decides the order when randomising is on; on a chart in fixed order it decided nothing, so “seed …” is now left out of the sheet's text, of the layout stamp and of the Create Chart log there. In a chart note of your own, {seed} goes with the words that only name it (“seed:”, “(seed {seed})”) and with the separator or brackets around it, so nothing like “seed:” or “()” is left behind; a word written with “:”, “#” or “=” right before {seed} counts as its name and goes with it; any other text stays as you wrote it.
  • The line down the edge of a ChromIQ layout engine chart (“Chart layout … | ChromIQ layout engine | ChromIQ …”) is centred on the patches, not on the paper. On a sheet with more paper above the patches than below it sat visibly off their middle. The patches themselves do not move.
  • The settings stamp down the right edge is no longer printed over white patches at the end of a page. On a chart in fixed order the last strip of the last page can be filled up with white patches, and the stamp (“Stamp settings down the right edge”, off unless you tick it) took them for paper and printed over up to 17 of them, without a warning. It now always starts right of the patches. Where there is no room there, it is printed over the patches as before, with the red warning in the Create Chart panel and a line in the log.
  • Ruler check (beta): a strip saved back to front right after a one-strip turn is asked about again, as in 4.3.41. After a turn the earlier way round is now kept as a second reference until the strips since the turn agree among themselves, not merely until three of them have been read.
  • Beta “M0, M1 and M2”: a temporary file left by a crash is cleared away. If ChromIQ's chart-reading engine stopped while writing a condition file, its temporary copy stayed in the run's “conditions” folder. It is now removed with the other files nothing needs any more (only that kind of file, only in that folder, and only when it is older than 10 minutes).

Honest limits

  • Margin tolerance: please do not lift the instrument off the ruler during a swipe. If it is lifted and set down again further along, the ruler cannot see the stretch it was carried over, and in rare cases a strip kept by this option can then be wrong. Every decision the option makes is recorded in the ruler diagnostics file, and we would very much like to have that file.
  • The margin tolerance has not yet been used with a real instrument. It was tested on the computer only: on wrong readings built on purpose from the expected colours of 28 real charts (none of them was kept, except the lifted instrument above), and on the recorded i1Pro 2 sessions of one tester, where it kept 10 of the 31 strips ArgyllCMS refused, each correctly.
  • i1iO charts of several pages: not yet tried with a real measurement of several sheets. The import has been tried with one real measurement of a single sheet and with measurement files that ChromIQ's own tests make up. When ChromIQ asks which page a file is, please check the page number and the corner patches it shows: a wrong answer would put the sheet's readings on the other page.
  • On an i1iO chart whose patch order is not randomised, the last sheet can be refused even when it was measured correctly, because it can end in patches that look alike. The Start window says so. If it happens, make the chart again with “Randomise patch order” ticked.
  • The ruler check is still a beta and has seen few real sessions. If you use it, the diagnostics file it writes helps us most.

Installation (Linux, beta): Download the tarball for your architecture (x86_64 for most desktops/laptops, aarch64 for ARM systems like Raspberry Pi 4/5). Extract with tar xzf ChromIQ-Linux-*.tar.gz, then run ./ChromIQ/ChromIQ. Requires ArgyllCMS: install it via your package manager (sudo apt install argyll) or from argyllcms.com/downloadlinux.html.


☕ ChromIQ is free and always will be. If it saves you time or ink, a coffee is a kind way to say thanks. Completely optional, and the app stays fully featured either way.

Support ChromIQ on Ko-fi