Added
Calibration: ADU to input-referred electrons and incident photons
(gf.Calibration, Camera.calibration). Calibration.from_camera(cam, exposure, n_darks=64, seed=...) averages exposure-matched dark frames into a
mean master dark on the camera's device and precision; to_electrons applies L^-1[(ADU - dark) * gain_e_per_adu / em_gain] / flat, inverting the
configured nonlinearity (closed form or Newton) by default; to_photons
divides by the scalar QE expose applies, a quantum_efficiency, the qe_curve at wavelength_nm, or its effective value over a bandpass; saturated flags pixels whose charge reached the input well, the output
register or the ADC ceiling. It works on NumPy and CuPy frames, takes an
optional unit-mean flat, and handles binned frames. Tests check that the mean
calibrated flux matches the incident photons to 0.5% for EMCCD, qCMOS, sCMOS,
eAPD, CCD and CMOS presets (issue #10).
Camera.effective_read_noise_e(binning=..., binning_mode=...): the
per-frame read noise referred to the input (electrons collected in the
pixel): output read noise (the quadrature mean of a per-pixel map), kTC/reset
noise and avalanche-scaled noise, divided by the EM/avalanche gain. The
docstring and the new guide give the excess-noise-factor SNR.
Guide: A WFS camera in a closed loop:
exposure vs. frame period, ADU calibration and its accuracy, input-referred
noise and the excess noise factor, recommended EMCCD/qCMOS/sCMOS/eAPD/CCD
presets, and keeping small frames cheap.
benchmarks/bench_small_frames.py: seeded 256x256 WFS frames for one preset
per detector class, with before/after comparison and a SHA-256 digest of
seeded output for bit-identity checks; results in benchmarks/small-frame-results.md.
Performance
Photon-starved EMCCD and eAPD frames are faster on the CPU, with
bit-identical seeded output. NumPy returns Gamma(shape=0) as exactly zero
without consuming a draw, but still visits every such pixel; the gain stage
now samples only the pixels that hold charge when they are a minority (a
wavefront sensor's dark background), and skips the * 1 shape scaling at F = sqrt(2). Same draws, same order, same generator state afterwards;
seeded frames of every preset, in both precisions, are bit-identical to 2.5.0.
On one Neoverse-N1 core (256x256 Shack-Hartmann spots, 1 ms, in-process A/B):
the Gamma draw 1.43 → 0.78 ms; whole frames andor_ocam2k 6.57 → 5.95 ms
(1.10x), leonardo_saphira 4.79 → 4.29 ms (1.12x), first_light_imaging_cred_one
7.16 → 6.63 ms (1.08x); presets without a gain stage are unchanged. The CPU
chain is otherwise at its sampler floor (about 85% of a frame is NumPy's
Poisson, Gamma and Gaussian draws). An exact vectorised replica of NumPy's
small-rate Poisson for the CIC draw was tried and measured no faster, so it
was not kept. See benchmarks/small-frame-results.md.
Documented
The 1--2% calibrated-flux deficit seen in the dithered Shack-Hartmann
prototype is not a deterministic offset of the signal chain: averaged over
300 frames the prototype recovers 1.002 (OCAM2K), 0.999 (ORCA-Quest 2) and
1.001 (generic sCMOS) of the incident flux, while a single 288x288 frame
scatters by 1.2%, 1.0% and 3.3%. The guide lists the deterministic offsets a
pipeline can introduce (median master dark, scalar vs. spectral QE,
nonlinearity, saturation, unflattened fixed patterns) and their remedies.
The Nüvü HNü 240 / 128 presets cap the amplified charge at their 500 / 800
e- full_well_e (no output_full_well_e), so at EM gain 1000 a pixel holding
one electron saturates; the guide warns about it (#11).