Added

  • Calibration: ADU to input-referred electrons and incident photons
    (gf.Calibration, Camera.calibration). Calibration.from_camera(cam, exposure, n_darks=64, seed=...) averages exposure-matched dark frames into a
    mean master dark on the camera's device and precision; to_electrons applies
    L^-1[(ADU - dark) * gain_e_per_adu / em_gain] / flat, inverting the
    configured nonlinearity (closed form or Newton) by default; to_photons
    divides by the scalar QE expose applies, a quantum_efficiency, the
    qe_curve at wavelength_nm, or its effective value over a bandpass;
    saturated flags pixels whose charge reached the input well, the output
    register or the ADC ceiling. It works on NumPy and CuPy frames, takes an
    optional unit-mean flat, and handles binned frames. Tests check that the mean
    calibrated flux matches the incident photons to 0.5% for EMCCD, qCMOS, sCMOS,
    eAPD, CCD and CMOS presets (issue #10).
  • Camera.effective_read_noise_e(binning=..., binning_mode=...): the
    per-frame read noise referred to the input (electrons collected in the
    pixel): output read noise (the quadrature mean of a per-pixel map), kTC/reset
    noise and avalanche-scaled noise, divided by the EM/avalanche gain. The
    docstring and the new guide give the excess-noise-factor SNR.
  • Guide: A WFS camera in a closed loop:
    exposure vs. frame period, ADU calibration and its accuracy, input-referred
    noise and the excess noise factor, recommended EMCCD/qCMOS/sCMOS/eAPD/CCD
    presets, and keeping small frames cheap.
  • benchmarks/bench_small_frames.py: seeded 256x256 WFS frames for one preset
    per detector class, with before/after comparison and a SHA-256 digest of
    seeded output for bit-identity checks; results in
    benchmarks/small-frame-results.md.

Performance

  • Photon-starved EMCCD and eAPD frames are faster on the CPU, with
    bit-identical seeded output.
    NumPy returns Gamma(shape=0) as exactly zero
    without consuming a draw, but still visits every such pixel; the gain stage
    now samples only the pixels that hold charge when they are a minority (a
    wavefront sensor's dark background), and skips the * 1 shape scaling at
    F = sqrt(2). Same draws, same order, same generator state afterwards;
    seeded frames of every preset, in both precisions, are bit-identical to 2.5.0.
    On one Neoverse-N1 core (256x256 Shack-Hartmann spots, 1 ms, in-process A/B):
    the Gamma draw 1.43 → 0.78 ms; whole frames andor_ocam2k 6.57 → 5.95 ms
    (1.10x), leonardo_saphira 4.79 → 4.29 ms (1.12x), first_light_imaging_cred_one
    7.16 → 6.63 ms (1.08x); presets without a gain stage are unchanged. The CPU
    chain is otherwise at its sampler floor (about 85% of a frame is NumPy's
    Poisson, Gamma and Gaussian draws). An exact vectorised replica of NumPy's
    small-rate Poisson for the CIC draw was tried and measured no faster, so it
    was not kept. See benchmarks/small-frame-results.md.

Documented

  • The 1--2% calibrated-flux deficit seen in the dithered Shack-Hartmann
    prototype is not a deterministic offset of the signal chain: averaged over
    300 frames the prototype recovers 1.002 (OCAM2K), 0.999 (ORCA-Quest 2) and
    1.001 (generic sCMOS) of the incident flux, while a single 288x288 frame
    scatters by 1.2%, 1.0% and 3.3%. The guide lists the deterministic offsets a
    pipeline can introduce (median master dark, scalar vs. spectral QE,
    nonlinearity, saturation, unflattened fixed patterns) and their remedies.
  • The Nüvü HNü 240 / 128 presets cap the amplified charge at their 500 / 800
    e- full_well_e (no output_full_well_e), so at EM gain 1000 a pixel holding
    one electron saturates; the guide warns about it (#11).