Fix async Modbus client and pymodbus 3.13 compatibility (v0.7.4)

  • Use AsyncModbusTcpClient with asyncio.Lock instead of the sync client
      run in an executor (read_modbus_data coroutine was never awaited)
  • Use device_id= instead of removed slave= keyword
  • Import pack/unpack_bitstring from pymodbus.pdu.utils (HA 2026.7)
  • Fix heat circuit 1 reader (not async, missing await)
  • Remove duplicated module reads and dead solar1/solar2 duplicates
  • Bump pymodbus to 3.13.1, min HA to 2026.7.0