File Object Details
| Field |
Value |
| File name |
Raspberry Pi Zero Battery - truemehta9.pca.json |
| File format |
.pca |
| File size |
3190 bytes |
| Image width |
2014 |
| Image height |
2024 |
| Color space |
BlackIsZero |
| Color depth |
16 |
| Compression |
Uncompressed |
| X pixel spacing |
0.2 |
| Y pixel spacing |
0.2 |
| Z pixel spacing |
0.2 |
| Pixel spacing units |
Mm |
| Slice thickness |
0.03275605 |
| Number of images in set |
1000 |
| 18 |
|
Image Acquisition Details
| Field |
Value |
| Modality |
X-Ray Computed Tomography (CT/microCT) |
| Device |
v |
|
| Device facility | Custom Build |
| Creator | johntrue15 |
| Event date | N/A |
| Software | phoenix datos|x 2.8.2.20099 |
| Filter | 0.1Cu |
| Exposure time | 333.096 ms |
| Flux normalization | Yes |
| Shading correction | Yes |
| Frame averaging | 3 |
| Projections | 1000
18 |
| Voltage | 140 |
| Power | 28.00 W |
| Amperage | 200 |
| Target material | Tungsten |
| Detector type | CMOS |
| Source object distance | 131.47875 mm |
| Source detector distance | 802.77534791 mm |
| Optical magnification | 6.10574217x |
| Attestation | https://github.com/johntrue15/NOCTURN-Raspi-test/attestations/5104451 |