Repository navigation
Instrument Data Parsers
Modern bioprocess and molecular biology workflows generate high-dimensional datasets across heterogeneous, vendor-locked proprietary file formats. The BioLabCalc analytical parser suite (biolabcalc.eln.parsers) provides zero-dependency, pure-Python ingestion engines that decode raw instrument outputs, normalize units, extract acquisition metadata, and index scientific data into the ELN and CAS blob store.
Fast Protein Liquid Chromatography (FPLC) is the primary technique for purifying recombinant proteins, enzymes, and therapeutic monoclonal antibodies. biolabcalc.eln.parsers.fplc_parser natively ingests Cytiva / GE Healthcare ÄKTA UNICORN and Bio-Rad NGC outputs across .res, .zip, .csv, and .asc formats.
┌────────────────────────────────────────────────────────────────────────────────────────┐
│ FPLC Multi-Channel Chromatogram │
│ 400 ┬ mAU Conductivity ┬ 50│
│ │ Peak 2 (Target T7RNAP) │ │
│ 300 ┼ ╭─╮ ┼ 40│
│ │ ╭╯ ╰╮ │mS │
│ 200 ┼ Peak 1 (Contaminant) ╭╯ ╰╮ Gradient %B ┼ 30│
│ │ ╭─╮ ╭╯ ╰╮ ┌───────────────────┤ │
│ 100 ┼ ╭╯ ╰╮ ╭╯ ╰╮ ╭╯ ┼ 20│
│ │ Flow-Through ╭╯ ╰╮ ╭╯ ╰╮ ╭╯ │ │
│ 0 ┴─────────────────┴───────┴─────────┴─────────────┴────┴──────────────────────┴──0│
│ 0 10 20 30 40 mL │
│ Fractions: [ A1 ][ A2 ][ A3 ][ A4 ][ B1 ][ B2 ][ B3 ][ B4 ][ B5 ][ C1 ][ C2 ] │
└────────────────────────────────────────────────────────────────────────────────────────┘
-
Multi-Wavelength Optical Detection: Simultaneous extraction of
$UV_{280}$ (tryptophan/tyrosine absorbance),$UV_{260}$ (nucleic acid co-elution check), and$UV_{215}$ (peptide backbone). - Physicochemical Traces: Conductivity (mS/cm), buffer gradient composition (%B), system pre-column pressure (MPa), and volumetric pump flow rate (mL/min).
-
Automated Fraction Mapping: Maps retention volume intervals to discrete fraction collector rack tube labels (
FractionEvent: ID, start volume, end volume, peak$UV_{280}$ ). -
Hardware & Column Metadata: Detects column bed volume (
$V_c$ ), void volume ($V_0$ ), pressure limits, and chemical mode (IMAC, SEC, IEX, HIC). -
Strict Scientific Data Integrity: Binary
.resstreams require embedded ASCII curve data. If unparseable binary streams are encountered,FPLCParserraises an explicitValueErrorrequesting the user export curves as CSV or ASC from UNICORN software rather than generating synthetic mock data.
from biolabcalc.eln.parsers.fplc_parser import FPLCParser
# Ingest an ÄKTA UNICORN run export (.res, .csv, or .zip)
result = FPLCParser.parse("run_T7RNAP_HisTrap_04.res")
print(f"Format: {result.file_format} | Data Points: {len(result.volume_ml)}")
print(f"Max UV280: {max(result.uv280_mau):.2f} mAU")
print(f"Fractions Collected: {len(result.fractions)}")
# Query target peak fraction
for frac in result.fractions:
if frac.peak_uv280_mau and frac.peak_uv280_mau > 150.0:
print(f"Target Tube {frac.fraction_id}: {frac.start_volume_ml:.2f}-{frac.end_volume_ml:.2f} mL (Peak: {frac.peak_uv280_mau:.1f} mAU)")Microvolume UV-Vis spectrophotometry provides rapid concentration and purity metrics for extracted nucleic acids and purified proteins. biolabcalc.eln.parsers.nanodrop_parser ingests exports from NanoDrop One, NanoDrop 2000, and NanoDrop Eight across .ndv, .tsv, .csv, and .xlsx formats.
-
Photometric Absorbance:
$A_{260}$ ,$A_{280}$ ,$A_{230}$ , and$A_{340}$ (turbidity/scatter baseline). -
Purity Ratios:
-
$A_{260}/A_{280}$ Ratio: Standard purity threshold (~1.80 for pure dsDNA, ~2.00 for pure RNA). Values$<1.65$ indicate protein contamination. -
$A_{260}/A_{230}$ Ratio: Assessment of organic contaminants. Values$<1.80$ flag residual guanidine thiocyanate, TRIzol reagents, or EDTA.
-
- High-Resolution Spectral Curve: Ingests continuous 220–350 nm UV spectra at 1 nm increments for publication-grade visualization.
- Automatic Contaminant Diagnostics: Identifies spectral shoulders characteristic of phenol (270 nm peak) or guanidine salts (intense absorbance below 240 nm).
from biolabcalc.eln.parsers.nanodrop_parser import NanoDropParser
# Ingest NanoDrop run export (returns NanoDropExperiment, which is directly iterable)
experiment = NanoDropParser.parse("nanodrop_plasmid_prep.tsv")
for s in experiment:
print(f"Sample: {s.sample_name} | Type: {s.sample_type}")
print(f" Concentration: {s.concentration:.2f} {s.concentration_units}")
print(f" A260/A280: {s.ratio_260_280:.2f} | A260/A230: {s.ratio_260_230:.2f}")
print(f" Diagnostic Assessment: {s.quality_assessment}")Ingests Bio-Rad Image Lab format (.scn) and 16-bit scientific TIFF files (.tif, .tiff) generated by ChemiDoc MP, GelDoc Go, and Odyssey imaging systems.
┌────────────────────────────────────────────────────────────────────────┐
│ SDS-PAGE Lane Densitometry │
│ Lane 1: Marker Lane 2: Lysate Lane 3: Flow-Thru Lane 4: Eluate │
│ ┌─────────────┐ ┌─────────────┐ ┌─────────────┐ ┌─────────────┐│
│ │ ─── 180 kDa │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ││
│ │ ─── 130 kDa │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ││
│ │ ─── 100 kDa │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ═══════════ ││ ◄ Target T7RNAP
│ │ ─── 70 kDa │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ (98.9 kDa) ││ (94.2% Purity)
│ │ ─── 55 kDa │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ≡≡≡≡≡≡≡≡≡≡≡ │ │ ││
│ └─────────────┘ └─────────────┘ └─────────────┘ └─────────────┘│
└────────────────────────────────────────────────────────────────────────┘
-
Exposure Metadata Extraction: Ingests sensor integration time, binning mode (
1x1,2x2), illumination chemistry (UV, Epi-White, Chemiluminescence, Stain-Free), and optical emission filter. -
16-Bit Dynamic Range Preservation: Avoids lossy 8-bit clipping. Linear intensity matrices (
$0 - 65,535$ arbitrary units) are preserved for true scientific densitometry. -
Logarithmic Molecular Weight Calibration: Fits relative migration distances (
$R_f$ ) of standard ladder rungs against known molecular weights:$$\log_{10}(\text{MW}) = a \cdot R_f + b$$ -
Purity Densitometry: Calculates target band area relative to the integrated intensity of all lane contaminants:
$$\text{Purity } (%) = \left(\frac{I_{\text{target}}}{\sum I_{\text{lane}}}\right) \times 100$$
Electrophysiology patch-clamp and voltage-clamp experiments recorded via Axon Instruments / Molecular Devices pCLAMP software produce Axon Binary Format (.abf) and Axon Text Format (.atf) files.
biolabcalc.eln.parsers.abf_parser provides a 100% pure-Python reader for both legacy ABF v1 (used in pCLAMP 6–9) and modern ABF v2 (pCLAMP 10+) without requiring compiled DLLs or non-standard C-extensions:
- Supported Modes: Gap-free continuous recording, episodic variable-loop stimulation, and event-driven sweeps.
-
Header & Protocol Decoding: Decodes sampling rate (
$Hz$ ), analog-to-digital converter (ADC) channels, holding potentials ($mV$ ), amplifier gain, and filter cutoff frequencies ($kHz$ ). -
Micro-Second Sweep Arrays: Extracts raw time-series arrays (
$pA$ ,$mV$ ) for every individual sweep episode. - Thumbnail Generation: Downsamples massive multi-gigabyte recordings into lightweight SVG / canvas coordinates for rapid web browser rendering.
Parses unstructured or semi-structured laboratory Markdown files, laboratory logs, and plain text bench files into structured protocol entities:
- Section Chunking: Detects standard header sections (Materials, Reagents, Setup, Reaction Mixture, Step-by-Step Procedure, Troubleshooting).
- Table Extraction: Automatically transforms ASCII and Markdown tables into structured dictionaries and Pandas-compatible dataframes.
-
Reagent Parameter Extraction: Uses regular expressions to extract incubation temperatures, shaker velocities (
$RPM$ ), centrifugal forces ($\times g$ ), and incubation times.
Laboratory scientists frequently take quick handwritten bench notes, hand-label microfuge tubes, or print thermal plate reader receipts. ocr_engine.py couples optical character recognition with domain-specific biochemical validation rules.
┌────────────────────────────────────────────────────────────────────────────────────────┐
│ Human-in-the-Loop (HITL) OCR Verification │
├──────────────────────────────────────────┬─────────────────────────────────────────────┤
│ Scanned Image Region │ Extracted Token & Verification │
├──────────────────────────────────────────┼─────────────────────────────────────────────┤
│ ┌──────────────────────────────────────┐ │ Token: 50 mM Tris-HCI, pH 7.5 │
│ │ 50 mM Tris-HCl, pH 7.5 │ │ Confidence: 0.74 (Ambiguous Character) │
│ └──────────────────────────────────────┘ │ BBox: [120, 45, 180, 24] │
│ │ Candidates: ["Tris-HCl", "Tris-HCI", "Tris"]│
│ │ │
│ │ [ Accept "Tris-HCl" ] [ Edit Value ] │
└──────────────────────────────────────────┴─────────────────────────────────────────────┘
Standard OCR engines frequently misinterpret biochemical strings due to shared character glyphs. The BioLabCalc engine applies automated contextual heuristics:
-
$O$ vs.$0$ : Distinguishes numeric concentrations (0.5 M) from chemical names ($O$-acetyl). -
$l$ vs.$1$ vs.$I$ : Differentiates volume units (10 µL) from Roman numerals (Complex I) and numbers (10 mM). -
Micro-Sign (
$\mu$ ) Restoration: NormalizesuL,ug, anduMinto standard SI symbols (µL,µg,µM).
When token confidence falls below 0.85, the engine flags the entity for operator inspection using standardized markup:
[[UNCERTAIN:id="tok_42" text="Tris-HCI" conf=0.74 bbox="[120, 45, 180, 24]" candidates="['Tris-HCl', 'Tris-HCI']"]]
This token is rendered in ocr_corrector.js as an interactive, highlightable form element where the scientist can confirm or edit the transcription with a single keystroke.
- Electronic Lab Notebook (ELN) — Web interface canvases for displaying parsed traces.
- SOP & Protocol Management — Instantiating parsed data into experimental checkoffs.
- RAG & Local AI Assistant — Indexing parsed analytical outputs into the hybrid search engine.
BioLabCalc Documentation Wiki | Licensed under the MIT License | GitHub Repository Research Use Only (RUO). Not intended for clinical or diagnostic procedures.
- Core Calculators & Stoichiometry
- Solution Prep & Spectroscopy
- Buffers & Precipitation
- Protein Quantification & Assays
- Fluorophores & Dye Labeling
- Molecular Cloning & Assembly
- Plasmid Engineering & Workbench
- PCR Kinetics & Primer Design
- In Vitro Transcription (IVT)
- Western Blotting Suite
- Bacterial Growth & Kinetics
- ELN System Architecture
- SOP & Protocol Management
- Instrument Data Parsers
- Inventory & Freezer LIMS
- Local RAG Knowledge Engine
- GxP Compliance & Audit Trails