Skip to content

Refute v0.5.0

Latest

Choose a tag to compare

@klucilla klucilla released this 20 Nov 13:33
Immutable release. Only release title and notes can be modified.

Refute 0.5.0: Stronger tests (closed as WEAKENED)

This release closes v0.5 Stronger tests. It makes the TESS battery say INCONCLUSIVE when a
test could not have failed, adds tests aimed at the spurious signals the v0.4 pilot exposed, and
measures the change against the v0.4 battery on the same curves. Every measurement was
pre-registered and locked before it ran, and is reported as it came out, pass or fail.
method_status: not_validated: no method of Refute is validated, and Refute reports verdicts
only, never a new planet.

Gate verdict: WEAKENED. All eight exit criteria are met, one of them with a recorded
deviation; the second independent gate review returned WEAKENED, with its issues open and
tracked (the first returned REFUTED because one criterion was not yet applied; both reports are
published as they came out, in calibration/v0.5/gate/). The
closing record is
calibration/v0.5/results/closing-record.md.
The verdict is about the phase's
completeness, never about any candidate.

What changed

  • A PASS needs the power to fail. A fatal or warning test passes only when it could have
    detected its declared minimum effect; otherwise it is INCONCLUSIVE, with its sensitivity
    reported. A sabotage case shows that a PASS without that sensitivity is impossible.
  • New decisive tests: a two-sided phase-0.5 check, a sinusoid test at P/2, P and 2P, a
    duty-cycle bound, events at segment edges, and the v0.5 rules of odd_even,
    aperture_depth, systematics and period_alias.
  • Built, but diagnostic only (they failed their own acceptance): single_event,
    event_consistency, and the per-sector centroid. The v0.5 battery has no decisive centroid
    test.

The trade-off, in numbers

Fewer spurious signals survive, and many more planets end INCONCLUSIVE.

  • Synthetic population (2,400 curves, run once): spurious survival fell to 0 for correlated
    noise, single events, edge ramps and variability (each family's upper 95 % bound between 2.5 %
    and 7 %; white noise passed the gate in only 4 of 200 curves, not decidable); planets with a
    pixel artifact, grazing planets and planets on variable stars were almost never refuted. But
    planets kept (SURVIVED or WEAKENED) fell from 96.8 % to 53.8 %, 32.7 % of a subset ended
    INCONCLUSIVE, and synthetic eclipsing binaries still survive: about 18 % (with a secondary) and
    22 % (at twice the period).
  • The 100 real light curves of the v0.4 pilot (both batteries, paired): surviving detections
    on inverted and rotated curves fell from 8 and 9 to 0; fewer of the original candidates
    survive, 2 to 0 among the 97 stars outside the three development stars (4 to 0 among all 100),
    though their truth is unknown; but of 637 recovered injected planets, 42.4 % survived or were
    weakened, against 99.7 % with v0.4.
  • 16 newly drawn real controls (8 known planets (NASA Exoplanet Archive), 8 catalogued
    eclipsing-binary false positives), without the catalog test: no planet REFUTED (3 SURVIVED, 1 WEAKENED, 4
    INCONCLUSIVE, against 6 SURVIVED and 2 WEAKENED with v0.4) and no false positive SURVIVED (1
    REFUTED, 4 WEAKENED, 3 INCONCLUSIVE). But v0.5 refuted fewer of the known false positives than
    v0.4 (1 against 2 of 8). These targets bound adverse outcomes; they do not measure successful
    classification.

Targets that failed

Recorded as results, with no rerun and no retuning: D1 for both synthetic eclipsing-binary
families, D2 and D4 (planets lost to INCONCLUSIVE), and T2a (injected planets kept).
The other declared targets passed (D1 for the noise, single-event, edge-ramp and variability
families, D3, D5, T2b, T2c, T3a, T3b); one family (white noise) was not decidable.

Structural findings (tracked)

  • #201: planets lost to INCONCLUSIVE.
  • #202: synthetic eclipsing binaries still survive, and no decisive test separates a low-mass
    stellar companion from a giant planet.
  • #203: the sinusoid test does not run above a 10-day period, so such candidates are INCONCLUSIVE
    before any data are read.
  • #204: the alias test's sensitivity simulation, counted at a fixed threshold, refuses passes the
    data support by a wide margin; one known false positive scored INCONCLUSIVE only for that
    reason.
  • #205: report wording found by the independent reviews.
  • #206: reproduction depends on a single host for the TESS-EB table.

Independent reviews of four drawn dossiers raised important objections and no critical one;
every objection is mapped to an issue (calibration/v0.5/reviews/objections-map.md).

Reproduction, with one recorded deviation

One new-control dossier was reproduced in a clean clone from its generated instructions, with
identical data hashes and key results within 1e-6. One input was placed by hand: the CDS
VizieR service did not answer (a cybersecurity incident announced by the CDS on 2026-10-28), so
the TESS-EB table was taken from the official mirror vizier.cfa.harvard.edu and verified against
the claim's content hash. The criterion as written requires nothing placed by hand; the
maintainer approved this single exception (#199, #206).

After v0.5: three correction rounds, the information checks, and a pause

v0.5 closed on 2026-11-05; this release is published on 2026-11-20. In between, the work stayed
on the same line, under the advance rule of the
ROADMAP. Under that rule, a new
capability phase starts only after every declared target passes or is shown to be infeasible.

  • v0.5.1, v0.5.2 and v0.5.3 Battery corrections closed as not approved. No target passed
    and none was declared infeasible
    (v0.5.1,
    v0.5.2,
    v0.5.3).
  • v0.5.4 Information checks was a change of approach after the third round, not a fourth
    round. It closed on 2026-11-13 without passing or failing a target
    (first half,
    second half).
  • The v0.5 line is paused by the maintainer's decision of 2026-11-13. The
    pause record
    gives, for each failed target (D1, D2, D4 and T2a) and for the new confirmation sample that
    T3b would need, what is known, what was not shown, and the evidence that would warrant
    reconsidering it.

No target was relaxed, none was declared infeasible, and no verdict changed: v0.5 stays
WEAKENED, and method_status stays not_validated. No corrected battery was approved: the
candidate batteries of the correction rounds are in the repository as development records only.