You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Reconstruction Explorer: repetitions are browsed by clicking the time course
or stepping the frame bar, and metabolites are labelled with colours and
contrast. Voxel plots of echo trains (EPSI, MGE) show the complex echo train
("Echoes") and its Fourier transform ("Spectrum"). The voxel plot has mode
buttons for Spectrum, FID and Time course, so CSI switches without the
settings column.
Explorer shows FID and spectrum for unencoded acquisitions such as the
internal single pulse instead of an empty reconstruction.
Spiral reconstruction in the Reconstruction Explorer with density-compensated
NUFFT, CG-NUFFT or linear gridding, optionally on k - Δk for the gradient
errors of the k-space tab.
k-Space Trajectory tab in the sequence workspace: k-space per readout or
frame, gradient/RF/ADC timeline, k(t), sampling PSF, and gradient delay, scale
and eddy-current settings applied live against the ideal trajectory.
Spiral trajectory designer ("Design…" next to the spiral revolutions) with
gradient and slew limits of the imaged nucleus, the gridding PSF, Apply to the
sequence and Export as .npz.
nufft.py with a Kaiser–Bessel NUFFT, Pipe–Menon density compensation and CG
reconstruction; spirals without a declared acquisition are detected from the
trajectory. The export notebooks explain which reconstruction fits each
readout and rerun spiral and radial reconstructions
(spiral_acquisition_from_metadata, reconstruct_spiral_frames).
PSF Analysis handles 2D spiral frames (point-source signal gridded with the
Pipe–Menon weights) and the gradient-error modes of the k-space tab.
Phantom designer: a "Simulated region" tab simulates only part of the phantom
(FOV around the isocentre and a ppm range), the default sphere is editable,
and a warning shows when the sequence FOV reaches beyond the simulated phantom
FOV.
Ideal-crusher banner when a generated sequence runs with gradient spoiling.
Bruker loader reads the applied gain (ACQ_CalibratedRG) and warns below
RG 10; SNR budget flags whole-object FID or brightest voxel below SNR 1 with
the averaging needed for SNR 3.
Changed
The Geometry tab is called Setup and zooms freely. Phantom + B1 is a sub-tab of
both Phantom and B1 Fields.
Sequence settings are shown per tab and hidden by default. Tab bars scroll
with two-finger gestures, and trackpad slice scrolling accumulates before a
slice step.
The "Sequence parameters changed" notice in Setup appears only when FOV,
matrix, slices or offsets change, not for timing edits such as TE or TR.
Analysis plots (PSF, spin probe, signal, Explorer) cannot be zoomed beyond the
data range. PSF plots are static.
SS-bSSFP defaults to the SLR pulse with sharpness 1.
The default scanner profile has gradient limits of 400 mT/m and 3000 T/m/s.
The advanced 13C bSSFP builders default to 400 mT/m and 4000 T/m/s.
Fixed
Sequence gradients use the gyromagnetic ratio of the imaged nucleus. 13C
sequences had about four times the physical gradient limit, and unknown
nuclei are rejected.
Readout ramps are at least the ADC dead time, and bSSFP keeps a centred ADC
at any bandwidth.
ADC time tolerance scales with scan duration, so long multi-repetition scans
no longer fall back to a wrong Cartesian reconstruction.
Loaded results saved without an acquisition layout get the inferred one, so
spirals saved before undeclared-spiral detection no longer show as a 1×N
image.
PSF Analysis no longer fails with NoneType after switching the k-space
plane.
Noise scans with non-white noise use the spectral-median sigma.
The PSF k-space modulation plot keeps a minimum y range.
Sequence preset files serialise numpy arrays, and pyqtgraph image items guard
against degenerate levels.
ParaVision exports write date stamps with English day and month names
whatever the locale of the exporting machine.