Repository navigation
LYSS 0.19.0: specification review before 1.0, stricter checks
Review of the specification before the 1.0 release candidate (specification 0.8.0-draft). No control was added or removed and no control ID changed. Several checks are stricter: a switch that passed with 0.18 can fail now. Rescan and read the list below.
Specification
- Advisory controls: from 1.0, a control added to an existing level within a major version is advisory: assessed and reported, but it never decides a level or a CI gate until the next major version. A switch that conforms to 1.x Level N keeps conforming to later 1.y versions.
- Terms defined: uplink, edge port, access port (an enabled edge port), user VLAN, management VLAN.
not_applicablemeans that what the control protects does not exist on the device. A missing security feature fails.- Parameters: assessed with the documented values; stricter values are allowed and stated in the claim.
Stricter checks
- LYSS-MGMT-010 covers every remote management path, not only SSH: web interface, SNMP and API on Cisco IOS, Arista, Huawei and SONiC.
- LYSS-ACC-011 on Cisco IOS also counts enabled ports left at the default mode.
- LYSS-MGMT-011 also fails an access port in a VLAN that carries a switch address on Juniper EX and MikroTik.
- Huawei: untagged hybrid ports are access ports. AOS-CX: switched ports without a
vlan accessline are access ports.
Fixes
- A switch without access ports (core, aggregation) can now reach Level 3: a level whose controls are all not applicable is met.
- Disabled ports are not access ports, on every platform.
- Junos: a RADIUS / TACACS+ secret stored as
$8$(master password) is no longer taken for cleartext. - SONiC Level 3 is "not applicable" only without untagged VLAN member ports, otherwise "unknown".
Known limit, unchanged: on MikroTik and SONiC, LYSS-ACC-011 only sees the ports marked as edge ports.
pip install "lyss==0.19.0" · Full changelog: CHANGELOG.md