  • Fix: a MANAGED TX waiting for a free channel no longer cuts off a frame that is still arriving. Since
    0.9.0 each CAD probe of the wait stopped the receiver before it looked and kept only a frame that had already
    completed, so while a TX waited the station lost the frame that kept the channel busy (every client that sends
    with MANAGED TX, and GET CHANNEL). A frame in progress now answers BUSY with reception left running, and
    the frame is received as usual; the TX waits as on any busy channel (CADWAIT unchanged).
    • SX1262: a preamble or a valid header latched without RxDone. LoRa RX now also latches PREAMBLE_DETECTED in
      the IRQ status (the RX interrupt still fires on RxDone only); FSK RX is unchanged.
    • SX127x: RegModemStat signal synchronized or header valid, unless RxDone is already latched. "RX on-going" is not
      used: on sx1276 boards it reads set on an idle channel all the time the receiver runs.
    • Trusted for at most the airtime of a 4-byte frame until a valid header, and of a 255-byte frame after it,
      from the first sighting; then the probe scans as before, at every probe, until the chip shows no frame once.
      A status that stays set can therefore not keep the channel BUSY.
    • Not covered: a frame whose first symbols arrive before the chip reports the preamble (SX127x, measured at
      SF8/BW125 with an 8-symbol preamble: a probe 24-47 ms after the frame's start still cut it in 8 of 19 early
      probes; signal synchronized never set on an idle channel), or during the CAD scan itself. Where the 255-byte
      airtime exceeds CADWAIT (SF12), a stale latched header ends the waiting TX as CHANNEL_BUSY, as a real frame
      of that length does. On SX127x, signal synchronized or header valid that flapped on and off on an idle channel
      would keep the MANAGED TX from keying again: the hold-off covers only a status that stays set (neither bit
      set on an idle channel in the measurement).