You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Fix: a MANAGED TX waiting for a free channel no longer cuts off a frame that is still arriving. Since
0.9.0 each CAD probe of the wait stopped the receiver before it looked and kept only a frame that had already
completed, so while a TX waited the station lost the frame that kept the channel busy (every client that sends
with MANAGED TX, and GET CHANNEL). A frame in progress now answers BUSY with reception left running, and
the frame is received as usual; the TX waits as on any busy channel (CADWAIT unchanged).
SX1262: a preamble or a valid header latched without RxDone. LoRa RX now also latches PREAMBLE_DETECTED in
the IRQ status (the RX interrupt still fires on RxDone only); FSK RX is unchanged.
SX127x: RegModemStat signal synchronized or header valid, unless RxDone is already latched. "RX on-going" is not
used: on sx1276 boards it reads set on an idle channel all the time the receiver runs.
Trusted for at most the airtime of a 4-byte frame until a valid header, and of a 255-byte frame after it,
from the first sighting; then the probe scans as before, at every probe, until the chip shows no frame once.
A status that stays set can therefore not keep the channel BUSY.
Not covered: a frame whose first symbols arrive before the chip reports the preamble (SX127x, measured at
SF8/BW125 with an 8-symbol preamble: a probe 24-47 ms after the frame's start still cut it in 8 of 19 early
probes; signal synchronized never set on an idle channel), or during the CAD scan itself. Where the 255-byte
airtime exceeds CADWAIT (SF12), a stale latched header ends the waiting TX as CHANNEL_BUSY, as a real frame
of that length does. On SX127x, signal synchronized or header valid that flapped on and off on an idle channel
would keep the MANAGED TX from keying again: the hold-off covers only a status that stays set (neither bit
set on an idle channel in the measurement).