Repository navigation
ARIEC60870 v3.6.17-rc.1
Pre-releaseArSee v3.6.17-rc.1 — Signal Map dropdown and toolbar acceptance
Release candidate · Windows x64 · 18 November 2026
This pre-release is for UI evaluation of the latest Signal Map engineering workbench. It is not a stable release, a protocol conformance certificate, or physical RTU/SCADA FAT evidence. The latest published stable fallback is v3.6.16.
Scope since stable v3.6.16
- PR #255 integrates the More circular icon-only action at 36×36 DIP, optically aligned with adjacent Add, Save, and Save & Apply 36-DIP pill controls. It inherits the same Main Window circular appearance and input-state template.
- Technical Signal Map fields now expose a compact native WPF dropdown of common IEC values with readable short labels and a secondary explanation for each option: IEC Type ID (TI), IEC Type/role, Class, COT, Command policy, TYPE/category, Engineering Unit, and Scaling Mode.
- Each selection saves the exact existing field code, not a UI description: e.g. TI 31 saves
31; IEC roleM_DP_TB_1and policyMonitorOnlyremain independent values. Non-catalogued project-specific codes remain editable. The UI never auto-pairs TI, role, unit, scaling, command policy or calibration from another choice. - Retains the stable grid-first workbench: native spreadsheet editing, filtering, Save/Apply validation, resizable inspector, paired two-point scaling, and current user-owned JSON profile schema. No IEC-101/103/104 parser, TX state machine, GI policy, physical serial wiring, command permission or source evidence changes.
Recommended desktop test (Signal Map)
- Back up the current engineering profile JSON first. For an isolated side-by-side evaluation, use the portable ZIP rather than upgrading a production installation.
- Open Signal Map and check that More remains circular and is exactly as tall as adjacent action pills.
- Choose digital TI 30 / TI 31 and analog TI 9 / TI 11 / TI 13 from the Mapping inspector; verify option descriptions and that the selected cell/JSON retain numeric codes.
- Check role, Class, COT, policy and category dropdowns; confirm no adjacent fields are silently rewritten. Choose an unfamiliar project-specific token, then verify edit/reopen fidelity.
- Confirm Scaling tab still exposes Factor and TwoPoint workflows with X0/X100/Y0/Y100; avoid interpreting IEC TI11 signed counts as MVar without authoritative field calibration.
- Confirm Save, Save & Apply, Copy/Paste, Undo/Redo, profile loading and the 31-point default profile have not regressed. If testing with an RTU, perform only site-authorized, isolated operations and retain source HEX.
Qualification and release invariants
The merged PR #255 passed Release build, formatting, protocol smoke, xUnit, native WPF acceptance, CodeQL, dependency review and repository hygiene; this RC's own Package workflow independently builds and checks its release source branch commit before publishing. Windows physical DPI 125/150%, genuine relay command transactions, SICAM serial handshakes, SOE/FIFO integrity, and verified field scaling remain NOT TESTED by these GUI gates. Unmerged IEC-101 P0 work in PR #145 is explicitly excluded.
Use the GitHub Release assets when and only when the Package run passes: ARIEC60870-v3.6.17-rc.1-setup-win-x64.exe, ARIEC60870-v3.6.17-rc.1-win-x64.zip, SHA256SUMS.txt, and SPDX SBOM. The immutable v3.6.17-rc.1 tag must refer to the accepted candidate source; do not replace the tag or republish different bytes under it.