Skip to content

ARIEC60870 v3.6.17-rc.1

Pre-release
Pre-release

Choose a tag to compare

@github-actions github-actions released this 18 Nov 04:49

ArSee v3.6.17-rc.1 — Signal Map dropdown and toolbar acceptance

Release candidate · Windows x64 · 18 November 2026

This pre-release is for UI evaluation of the latest Signal Map engineering workbench. It is not a stable release, a protocol conformance certificate, or physical RTU/SCADA FAT evidence. The latest published stable fallback is v3.6.16.

Scope since stable v3.6.16

  • PR #255 integrates the More circular icon-only action at 36×36 DIP, optically aligned with adjacent Add, Save, and Save & Apply 36-DIP pill controls. It inherits the same Main Window circular appearance and input-state template.
  • Technical Signal Map fields now expose a compact native WPF dropdown of common IEC values with readable short labels and a secondary explanation for each option: IEC Type ID (TI), IEC Type/role, Class, COT, Command policy, TYPE/category, Engineering Unit, and Scaling Mode.
  • Each selection saves the exact existing field code, not a UI description: e.g. TI 31 saves 31; IEC role M_DP_TB_1 and policy MonitorOnly remain independent values. Non-catalogued project-specific codes remain editable. The UI never auto-pairs TI, role, unit, scaling, command policy or calibration from another choice.
  • Retains the stable grid-first workbench: native spreadsheet editing, filtering, Save/Apply validation, resizable inspector, paired two-point scaling, and current user-owned JSON profile schema. No IEC-101/103/104 parser, TX state machine, GI policy, physical serial wiring, command permission or source evidence changes.

Recommended desktop test (Signal Map)

  1. Back up the current engineering profile JSON first. For an isolated side-by-side evaluation, use the portable ZIP rather than upgrading a production installation.
  2. Open Signal Map and check that More remains circular and is exactly as tall as adjacent action pills.
  3. Choose digital TI 30 / TI 31 and analog TI 9 / TI 11 / TI 13 from the Mapping inspector; verify option descriptions and that the selected cell/JSON retain numeric codes.
  4. Check role, Class, COT, policy and category dropdowns; confirm no adjacent fields are silently rewritten. Choose an unfamiliar project-specific token, then verify edit/reopen fidelity.
  5. Confirm Scaling tab still exposes Factor and TwoPoint workflows with X0/X100/Y0/Y100; avoid interpreting IEC TI11 signed counts as MVar without authoritative field calibration.
  6. Confirm Save, Save & Apply, Copy/Paste, Undo/Redo, profile loading and the 31-point default profile have not regressed. If testing with an RTU, perform only site-authorized, isolated operations and retain source HEX.

Qualification and release invariants

The merged PR #255 passed Release build, formatting, protocol smoke, xUnit, native WPF acceptance, CodeQL, dependency review and repository hygiene; this RC's own Package workflow independently builds and checks its release source branch commit before publishing. Windows physical DPI 125/150%, genuine relay command transactions, SICAM serial handshakes, SOE/FIFO integrity, and verified field scaling remain NOT TESTED by these GUI gates. Unmerged IEC-101 P0 work in PR #145 is explicitly excluded.

Use the GitHub Release assets when and only when the Package run passes: ARIEC60870-v3.6.17-rc.1-setup-win-x64.exe, ARIEC60870-v3.6.17-rc.1-win-x64.zip, SHA256SUMS.txt, and SPDX SBOM. The immutable v3.6.17-rc.1 tag must refer to the accepted candidate source; do not replace the tag or republish different bytes under it.