ArSee v3.6.17-rc.2 — Event FC evidence and SCADA scaling review

Windows x64 · Public release candidate · 18 November 2026

This candidate extends v3.6.17-rc.1, keeping its compact Material toolbar, Excel-like Signal Map, descriptive IEC dropdowns, and shared WPF styles. It does not replace the latest stable v3.6.16.

Changes since rc.1

  • #256: Event Log FC column shows FC10 (IEC-101 Request user data, Class 1) or FC11 (Request user data, Class 2) only with a verified source/link-qualified request–response pair; unmatched/other-protocol events show —. Hover explains that FC11 can carry Class 1 fallback and that FC10/FC11 describes the observed poll, not a permanent IOA class. The RequestFC evidence is also included in Event CSV.
  • #257: reconcile operator-supplied eTerra SCADA range reference, including the later correction POAQ TI9 measured feedback 0–1200, distinct from POOP TI48 outbound setpoint 0–1000. Default profile retains the 31 CA/IOA/TI points and safe uncalibrated TI11 Q counts. Inbound TI9 uses TwoPoint: X0=0, X100=1, Y0=0, Y100=1200 on decoded NVA per-unit, not 32767 raw counts.
  • #258: optional Signal Map → select a signal → More → SCADA reference range for selected signal.... Deliberately opt-in choices: Q Diri Sendiri signed raw −32768..32767 to engineering ±2078, Q Lab same raw to ±260, or corrected POAQ feedback 0–1200. Only matching CA105/IOA/TI measurement points; shows a confirmation and supports Ctrl+Z. The photographed Q data items were not mapped to specific FEEDER/KOPEL/TRAFO IOAs; no bulk Q assignment, no command encoder changes.
  • #259: audit fix. Sync 31 I/O reference now correctly labels POAQ 0–1200. When an unverified SCADA reference range is first staged, the editor requires Save As to a new JSON file, prevents saving to the original station profile, and permits subsequent edits in the new copy. Adds field-isolation/rollback regression tests, including preservation of POOP setpoint.

Short test checklist

  1. For a non-destructive trial use the portable ZIP and back up the user-owned mapping JSON. Load the 31-point reference profile; confirm POAQ 790449 (TI9) feedback span 0–1200 and POOP 70537 (TI48) metadata 0–1000.
  2. Select one Q TI11, choose a Q reference under More, verify X0/X100/Y0/Y100, then test Ctrl+Z. Do not accept Q Diri Sendiri versus Q Lab for a particular IOA until eTerra and RTU evidence match.
  3. Apply one reference, press Save or Save & Apply, and verify the app requests a new JSON filename instead of overwriting the original. Attempting the original file path must be refused.
  4. Open Event Log during a source-qualified IEC-101 unbalanced poll capture: matched FC10 and FC11 responses show their real request FC; missing TX, mismatched source, and IEC-104 show —. Verify tooltips and Event CSV export.
  5. Confirm search/filter, direct cell edit, Undo/Redo, Mapping/Scaling tabs and shared style have not regressed.

Engineering limits

The photographed SCADA note suggests S = √3 × 500 kV × 2000 A ≈ 1732.05 MVA; 120% ≈ 2078.46 MVA. The Q Diri Sendiri ±2078 and Q Lab ±260 endpoints remain reference ranges, not confirmed per-IOA calibration. A full-scale TI11 signed mapping has a small nonzero output at raw=0 due to asymmetric −32768..32767 limits; do not silently force zero centering. TI32 tap positions and TI13 float units are not inferred from this photo. SCADA endpoint equality requires live RX bytes, source data-item association, known configuration revision and independent FAT proof.

No physical RTU/SCADA, 1200-bps SOE, 125/150% DPI, or command execution FAT is claimed from CI. IEC-101 P0 work #145 remains unmerged and excluded. This RC must not be advertised as production IEC conformance or station calibration approval.

Distribution and provenance

Publish only after the exact-source Package workflow succeeds and verifies portable executable GUI, installer, checksums, SPDX SBOM, and attestations. Official assets:

  • ARIEC60870-v3.6.17-rc.2-setup-win-x64.exe
  • ARIEC60870-v3.6.17-rc.2-win-x64.zip
  • SHA256SUMS.txt and the published SBOM/provenance

The v3.6.17-rc.2 tag is immutable. Never reuse RC.1 or overwrite its released bytes.