Repository navigation
ardirec v0.2.0-alpha.14 — Table UX Finalization
Pre-release
Pre-release
·
314 commits
to main
since this release
alpha.14 finalizes the Engineering Table UX after alpha.13 achieved numerical parity with the SIGRA line1.CFG reference.
Table UX changes:
- Record sorting now preserves the actual COMTRADE CFG analog-channel order instead of silently grouping voltage before current.
- Table-specific top chrome is collapsed so more engineering rows remain visible while Open, Signals, view switching and Primary/Secondary remain accessible.
- Analysis rows are denser and use one-decimal percentages for fast scanning; Detailed mode and hover tooltips preserve additional precision.
- Column semantics are explicit: DC/H1 and THD H2-Hn make the percentage reference and Nyquist-safe THD range unambiguous.
- Abnormal investigation cues use restrained amber markers instead of large filled warning cells; they remain heuristics, not relay-operate verdicts.
- Summary wording is more direct: Worst THD, Highest DC/H1, Max V RMS and Max I RMS.
- Detailed mode keeps nearest sample, true RMS, crest factor and signed DC without changing the single-cursor investigation context.
Calculation behavior from alpha.13 is intentionally unchanged: cursor-referenced phase, Last extremum, DC/H1, Nyquist-safe harmonics and THD remain the validated baseline.
Windows development distribution remains a portable ZIP folder. The executable is unsigned, so Windows SmartScreen may show a warning.
What's Changed