Repository navigation
Graywolf RXT test build 636d1ab9
Pre-releaseFixes CA2RXU signed commands rejected with "bad tag" when an iGate uses a Tactical Callsign.
In Messages, open the conversation where the existing key is installed, then choose the lightning-bolt panel and Key settings. Set "RF recipient / Destinataire RF" to the on-air name (for example BURNTX), and "iGate Callsign-SSID (signed identity)" to the iGate's Station Callsign-SSID (for example N7UV). Leave the secret blank and save. The existing key and counter are preserved, and Graywolf opens the RF destination conversation. Verify RF only and the intended LoRa channel before sending. No firmware update is required.
Existing keys are migrated automatically with their previous target as the signed identity. Without a tactical name, no configuration change is needed. Restart Graywolf after upgrading and refresh the browser. The radio command format is unchanged.
Validation: protocol reference vector, database migration, counter preservation, API tests, browser editing and destination navigation, and 581 web tests passed. An EcoMode command was confirmed working on the operator's tactical iGate. Other devices still require their own RF validation. Queued status and an APRS ACK do not prove command execution; check the device response and state.
Documentation: English walkthrough, French walkthrough, with PDFs included in the handbook.
Commit: 636d1ab. Base version: 0.14.14. RXT pre-release for testing. No OCI images; GHCR latest unchanged.