Repository navigation
v3.0.0
Windows App Manager MCP 3.0.0 is a breaking release. It finishes the clean-up that 2.2.0 announced: tools that another tool replaced are gone, every tool names a monitor one way, and get_ui_elements returns its compact text by default. Nothing new is added. A client that already uses the replacements keeps working; check the list below if your prompts, scripts or settings still name an old tool or monitorIndex.
The release still needs the .NET 10 Desktop Runtime (x64), as 2.5.0 does.
Breaking
Nine tools removed
They had been off by default since 2.2.0, in the opt-in deprecated toolset, which is removed too.
| Removed tool | Use instead |
|---|---|
click |
mouse_click |
right_click |
mouse_click with button: "secondary" |
double_click |
mouse_click with clickCount: 2 |
move_window |
set_window_bounds with x and y |
resize_window |
set_window_bounds with width and height |
get_all_windows |
find_windows with no filter |
get_primary_monitor |
get_monitors (the monitor with isPrimary) |
list_screens |
get_monitors (its virtualScreen) |
get_active_browser_url |
get_browser_url with window: {"foreground": true} |
- A call to a removed tool fails with the new error code
ToolRemoved, and the error names the tool to call instead. Nothing is done, and the call is never passed on to the replacement. - Old settings still work.
WAM_EXCLUDE_TOOLSthat names a removed tool ordeprecatedis accepted; the tool is gone anyway. InWAM_TOOLSETS,+deprecatedand-deprecatedare ignored with a warning inget_server_info.deprecatedalone still serves only theservertoolset, as an unknown name always did, because the default would serve more than you asked for.
monitorIndex removed
Pass monitor instead: it takes the index, or a name such as "primary", "left", "right" or a monitor id from get_monitors.
- Where:
take_screenshot,snap_window,move_window_to_monitor,read_screen_text,find_text_on_screen,wait_for_visual, theplacementoflaunch_application,launch_applications_batchandlaunch_browser_with_debug, and the items ofsnap_windows_batch. - A call that still passes it fails with
InvalidArguments, and the error says to usemonitor. A placement or batch item with a field it doesn't take is refused the same way, so a window never lands on another monitor than you meant. move_window_to_monitornow requiresmonitor.- Unchanged: results still report the window's
monitorIndex, and layout files keep theirs.
Changed
get_ui_elementsreturns text by default: one compact line per element, such asw4120035e17 Button 'Save' aid=SaveBtn @812,44 80x24. A typical window costs about 2,500 tokens instead of about 6,000. Passformat: "tree"for the JSON tree, or"flat"for the flat list.- Smaller tool list: about 65,700 tokens for all 78 tools (it was about 70,900 for 87). The default tool list keeps its 62 tools.
Upgrading
- Search your prompts, scripts and agent instructions for the nine tool names and
monitorIndex, and switch to the replacements above. - If you read
get_ui_elements'elements, addformat: "tree". - Remove
deprecatedfromWAM_TOOLSETS(optional; it's ignored).
See Removed and moved tools for details.