Repository navigation
Rigwright v0.1.29
What's Changed
Fixed
- Make
SHfilter-width set and answer layouts model-owned. FT-991A uses
one fixed selector before the two-digit width index (SH001;for index 1);
FT-710, FTDX10, and FTDX101D/MP retain their additional reserved field
(SH0001;). Correct FT-991A readback to acceptSH012;for index 12. - Validate the profiled selector/reserved prefix when decoding width answers.
Tests and evidence
- Check exact read/write frames for all five modern Yaesu models, malformed
FT-991A answers, and frequency polling after a width read. Command layouts
were checked against the official CAT manuals. - Investigated a QSONaut 0.4.0 report where FT-991A CAT polling failed after
applying an FT8 preset. The malformed write is confirmed in software;
physical-radio confirmation of the full timeout sequence remains pending. - This release corrects CAT framing. Application preset bandwidth selection
and model/mode-specific bandwidth tables need a separate audit; width index
1 is not a universal digital-mode bandwidth preset.
Full Changelog: v0.1.28...v0.1.29