v0.2.0 — Front-panel button fix and 64-bit support
The Rigol DG822 Pro plugin now supports both 32-bit and 64-bit FRA4PicoScope on Windows. This release also fixes a bug that could leave the generator’s front-panel buttons locked after closing FRA4PicoScope.
Installation
-
Download the ZIP that matches your FRA4PicoScope version.
FRA4PicoScope version Download 32-bit (x86) RigolDG822-x86.zip64-bit (x64) RigolDG822-x64.zip -
Close FRA4PicoScope and extract
RigolDG822.dllinto the folder containingFRA4PicoScope.exe. Replace the previous DLL if you’re upgrading. -
Make sure your VISA runtime supports the same architecture, then reopen FRA4PicoScope.
Troubleshooting
If a sweep shows an error or stops responding, enter CH=1;LOAD=HIGHZ;TIMEOUT=4000 in the external generator’s initialization field and retry. This setting worked on the tested DG822 Pro setup.
v0.1.1 — Rigol DG822 Pro plugin
v0.1.1 — Bug Fixes & VISA Communication Improvements
This update improves the reliability of the Rigol DG822 Pro external signal generator plugin for FRA4PicoScope.
What's Changed
- Fixed the
ExtSigGen.hinclude path to resolve compilation errors. - Optimized VISA communication timing to reduce instrument communication errors.
- Improved frequency-change synchronization during frequency response sweeps.
Installation
- Install a compatible VISA runtime (such as NI-VISA) if it is not already installed on your computer.
- Download
RigolDG822.dllfrom the assets below. - Place
RigolDG822.dllin the same folder as your FRA4PicoScope executable. - Connect your Rigol DG822 Pro to your computer.
- Start FRA4PicoScope.
Requirements
- FRA4PicoScope (32-bit)
- Rigol DG822 Pro function generator
- Compatible VISA runtime (such as NI-VISA)
Note: This is a maintenance release focused on stability and communication reliability.
v0.1.0 — Rigol DG822 Pro plugin
First working release of the Rigol DG822 Pro external signal-generator plugin for FRA4PicoScope.
The plugin allows FRA4PicoScope to control the generator through VISA and SCPI for automated frequency-response measurements.
Features
- Automatic USB discovery of compatible DG822 generators.
- Sine-wave frequency, amplitude, and DC offset control.
- Channel 1 or 2 selection.
- High-impedance or 50 Ω load settings.
- Instrument error checks and improved communication failure handling.
- Output shutdown and front-panel unlocking during normal termination.
Tested setup
- Rigol DG822 Pro connected through USB.
- PicoScope 2406B.
- FRA4PicoScope with a Windows 32-bit plugin build.
Installation
- Download the attached
RigolDG822.dll. - Install a VISA runtime that supports 32-bit applications.
- Place the DLL in the external signal-generator plugin location used by your FRA4PicoScope installation.
- Restart FRA4PicoScope and select the Rigol generator.
The DLL architecture must match your FRA4PicoScope application.
High-frequency sweep setting
With the tested 500 MS/s capture configuration, set Tools → Settings → Low noise oversampling to 16 for sweeps up to 20 MHz. The default setting of 64 requests sampling rates above 500 MS/s beyond approximately 7.8 MHz.
Release status
This is an early release tested on the setup above. Reports from other configurations are welcome. When reporting an issue, include your FRA4PicoScope version, VISA implementation, generator model, and error log.