Skip to content

v1.7.0

Choose a tag to compare

@nocoo nocoo released this 15 Mar 00:01
· 66 commits to main since this release

Features

  • Add MetricsDetector protocol for periodic system metrics analysis alongside log-based pattern detection
  • Add P15 Sustained High CPU detector — warns when CPU usage exceeds 80% for 60+ seconds, escalates to critical when combined with thermal pressure
  • Add P16 Thermal State detector — alerts on ProcessInfo.ThermalState transitions to .fair/.serious/.critical
  • Add generic MetricsThresholdDetector with sustained duration tracking, hysteresis recovery, and configurable warning/critical thresholds
  • Add P17 Memory Pressure detector — warns at >85%, critical at >95%, recovery ≤80% (30s sustained)
  • Add P18 Swap Usage detector — warns at >4 GB, critical at >8 GB, recovery ≤3 GB (30s sustained)
  • Add P19 Disk Usage detector — warns at >85%, critical at >95%, recovery ≤80% (60s sustained)
  • Add macOS system notification banners (UNUserNotification) when alerts are activated or upgraded in severity
  • Add notificationsEnabled setting (default: on) to control notification banners
  • Enable swap and disk metrics sampling in background mode for always-on detector coverage

Bug Fixes

  • Guard UNUserNotificationCenter calls against missing bundle identifier to prevent crash in SPM debug builds

Tests

  • Add 10 tests for SustainedCPUDetector state machine (normal/elevated/warning/critical/recovery)
  • Add 8 tests for ThermalStateDetector state transitions
  • Add 13 tests for MetricsThresholdDetector (state transitions, hysteresis, direct-to-critical, disabled)
  • Add 3 smoke tests for P17/P18/P19 pattern factories (ID, initial state, metric extraction)
  • Add 4 tests for AlertStateManager.onAlertActivated callback (promote, upgrade, no-fire on refresh/downgrade)
  • Add 3 tests for AppSettings.notificationsEnabled (default, toggle, reset)
  • Update pipeline and catalog test counts from 17 to 20 detectors