Releases
v1.7.0
Compare
Sorry, something went wrong.
No results found
nocoo
released this
15 Mar 00:01
Features
Add MetricsDetector protocol for periodic system metrics analysis alongside log-based pattern detection
Add P15 Sustained High CPU detector — warns when CPU usage exceeds 80% for 60+ seconds, escalates to critical when combined with thermal pressure
Add P16 Thermal State detector — alerts on ProcessInfo.ThermalState transitions to .fair/.serious/.critical
Add generic MetricsThresholdDetector with sustained duration tracking, hysteresis recovery, and configurable warning/critical thresholds
Add P17 Memory Pressure detector — warns at >85%, critical at >95%, recovery ≤80% (30s sustained)
Add P18 Swap Usage detector — warns at >4 GB, critical at >8 GB, recovery ≤3 GB (30s sustained)
Add P19 Disk Usage detector — warns at >85%, critical at >95%, recovery ≤80% (60s sustained)
Add macOS system notification banners (UNUserNotification) when alerts are activated or upgraded in severity
Add notificationsEnabled setting (default: on) to control notification banners
Enable swap and disk metrics sampling in background mode for always-on detector coverage
Bug Fixes
Guard UNUserNotificationCenter calls against missing bundle identifier to prevent crash in SPM debug builds
Tests
Add 10 tests for SustainedCPUDetector state machine (normal/elevated/warning/critical/recovery)
Add 8 tests for ThermalStateDetector state transitions
Add 13 tests for MetricsThresholdDetector (state transitions, hysteresis, direct-to-critical, disabled)
Add 3 smoke tests for P17/P18/P19 pattern factories (ID, initial state, metric extraction)
Add 4 tests for AlertStateManager.onAlertActivated callback (promote, upgrade, no-fire on refresh/downgrade)
Add 3 tests for AppSettings.notificationsEnabled (default, toggle, reset)
Update pipeline and catalog test counts from 17 to 20 detectors